-64-
REMOTE ADMINISTRATION & MAINTENANCE PROCEDURES
SECTION 400-096-600
SEPTEMBER 1992
TABLE RM-BS
SYSTEM DATE/DAY/TIME SETTING PROCEDURE
ACTION
STEP
DISPLAY/PRINTOUT
1
>MODE TEST
T
Enter the Test Mode
At the >MODE prompt, enter
T E S T CR
.
2
T TK00 K01 651YYMMDD#
T
To Set Date
3
To Set Time Of Day
Enter
T K 0 0 K 0 1 6 5 1 Y Y M M D D # CR
.
4
5
To Exit the Test Mode
At T prompt, enter
Q U I T CR
.
TTK00 K01 652HHMMSS#
Enter
T K 0 0 K 0 1 6 5 2 H H M M S S # CR
.
To Set Day Of The Week
Enter
T K 0 0 K 0 1 6 5 3 D # CR
.
(D = day of week with Sunday = 1 ~ Saturday = 7)
TTK00 K01 653D#
T