REMOTE ADMINISTRATION & MAINTENANCE PROCEDURES
SECTION 400-096-600
SEPTEMBER 1992
-12-
IMPORTANT NOTE:
If all programs are initialized, the "IMDU enabled" has also been turned off in Program 77-1, LED
14. If using the IMDU for remote programming, go into Program 77-1 and turn Button/LED 14
on as shown in Steps 9, 10, and 11. If this is not completed, remote programming must be
reactivated locally from the programmed digital or electronic telephone.
TABLE RM-C
PROGRAM 90
INITIALIZING PROGRAMS 00 ~ 97
ACTION
STEP
DISPLAY/PRINTOUT
1
>MODE PROG
Enter the Program Mode
At the >MODE prompt enter
P R O G CR
.
2
P 90
P90
Enter Program Number 90
Press
CR
.
3
P90 00-97
To Initialize All Programs Enter
0 0 * 9 7
NOTE: Single programs can be initialized by entering a single
program number plus
#
. Group numbers are separated by an
*
.
4
P90 00-97 01 N
Enter button/LED number
0 1
.
5
P90 00-97 01 N Y
Change LED 01 to “ON” by entering
Y
.
7
8
Press
CR
.
Press
SPACE
.
6
P90 00-97 01 N Y
02 N Y
Initialization complete.
P90 00-97 01 N Y
P90
02 N Y
P90 00-97 01 N Y
02 N
9
10
11
12
Exit Program 90
Press
# # CR
.
P90 # #
P
Enter Program 77
Press
7 7 CR
.
P77
then:
Y CR
.
Press
1 1 4
.
P77 1 14 N
P77 1 14 N Y
P77
To Exit this Program:
Press
# # CR
.
NOTE: If program data is not entered correctly, then
CR
will
not respond. To retry, press
DELETE CR
.
Change LED 02 to “ON” by entering
Y
.
Summary of Contents for Strata DK 24
Page 2: ......
Page 10: ......
Page 12: ...INSTALLATION SYSTEM DESCRIPTION SECTION 400 096 202 SEPTEMBER 1992 ...
Page 42: ......
Page 72: ......
Page 102: ......
Page 110: ......
Page 144: ...INSTALLATION TELEPHONE SECTION 400 096 207 SEPTEMBER 1992 ...
Page 164: ......
Page 166: ...INSTALLATION PERIPHERALS SECTION 400 096 208 SEPTEMBER 1992 ...
Page 170: ......
Page 238: ...INSTALLATION WIRING DIAGRAMS SECTION 400 096 209 SEPTEMBER 1992 ...
Page 300: ......
Page 302: ...REMOTE ADMINISTRATION MAINTENANCE PROCEDURES SECTION 400 096 600 SEPTEMBER 1992 ...
Page 372: ......