STRATA DK FAULT FINDING
SECTION 400-096-500
SEPTEMBER 1992
-8-
CHART NO. 2
POWER FAULTS
END
Did
you arrive
here from the
Fault Classification
Flowchart?
PWR
Pages 6
& 10
NO
From
Power down and
lightly press all
power supply
circuit breakers.
YES
Is
fault
cleared?
YES
Remove all
PCBs and power
down and press
breakers.
NO
Is
power
present at the
power supply and
backplane connectors
P1,
P4?
Refer to Voltage
Distribution Tables
B, C, and D and
install PCBs one at a
time until faulty PCB
is found.
YES
Call Service
Center for
assistance.
Did
replacement
of the faulty PCB
correct the
problem?
Is
fault
cleared?
Tag the
defective unit(s)
and return for
repair.
YES
Replace
power
supply.
NO
YES
NO
NO
Go to
Page 6
to classify
fault.
Start here to clear
Power faults.