8-36
INSTALLATION-PERIPHERALS
SECTION 400-096-208
SEPTEMBER 1992
01 DISA 12:22 00:02;01 (incoming)
Disconnect Timer:
01 DISA 12:24 00:04;57 (incoming)
03 DISA 12:24 00:04;57 (outgoing)
NOTE:
The "MSS" entry will print out only if the call
was originated after the SMDR threshold, 1.0
or 10 seconds. The threshold is set in Pro-
gram 60-2.
8.03 System Program Data Printout. If a printer
is connected to the SMDR port, customer program
information stored in the PCTU or PCTUS RAM
may be printed out for reference by using Program
97 (see Paragraph 8.14).
8.10 SMDR Hardware Requirements
8.11 A DK system must be equipped with a PIOU
or PIOUS PCB to support the SMDR printer/call
accounting device option. Connection of the printer
or call accounting device to the PIOU or PIOUS
PCB is accomplished with a 3-pair modular cord
(7 feet maximum) and a PPTC connector adaptor
(Figure 8-24). Call record data is ASCII-formatted,
8 bits, no parity, 1-stop bit.
8.12 The PIOU or PIOUS contains a call record
buffer which stores call record data (for up to 50
calls) when the printed or call accounting device is
turned off, or when no device is connected to the
SMDR port. No further call records are stored after
the buffer is filled. When the printer or call account-
ing device is made operational, an “ERROR
BUFFER OVERFLOW” message is printed to indi-
cate that the buffer was full, and that some call
information may have been lost.
8.13 SMDR Programming Considerations
8.14 Selectable programming options for the SMDR
printer or call accounting device are as follows:
Program 60
•
Item 2 (Release 4 only)—Selects the minimum
duration (1.0 or 10 seconds) of calls that will be
registered by SMDR . Any call that lasts less than
the set time will not be recorded.
•
Item 3—Selects the records of outgoing calls or
outgoing and incoming calls to be printed.
•
Item 4—Selects the digit length of Account Codes
(4 to 15 digits).
•
Item 5—Allows only long distance call records to
be printed.
Program 97
•
Allows system program data to be printed via the
SMDR port (Figure 8-23).
NOTES:
1. An SMDR printer must be connected to
the SMDR port to use the printout option
selected by Program 97.
2. Call record data is lost when program data
is printed out using Program 97.
8.20 SMDR Printer/Call Accounting Device
Installation
8.21 Install the SMDR printer/call accounting de-
vice option in accordance with the following steps:
(Refer to Figure 8-24 and related drawings in
Chapter 9.)
1) Connect the interface cable and the PPTC
adaptor from the PIOU or PIOUS SMDR port
to the SMDR printer or call accounting device
DB25 connector.
2) Set the PIOU or PIOUS SW1 switch to the
appropriate baud rate (300 or 1200 bps), as
determined by the baud rate of the printer or
call accounting device.
3) Set the printer or call accounting device to
8-bits/no parity/one stop bit.
4) Program (Program 60) the system for the
required SMDR printer/call accounting device
options (refer to Paragraph 8.13 and the Pro-
gramming Procedures, Section 400-096-300).
9 MAINTENANCE TERMINAL OPTIONS
9.00 A customer-supplied maintenance terminal
may be connected to the system (PIOU or PIOUS)
either locally or remotely. The maintenance termi-
nal (ASCII terminal) allows system programming
Summary of Contents for Strata DK 24
Page 2: ......
Page 10: ......
Page 12: ...INSTALLATION SYSTEM DESCRIPTION SECTION 400 096 202 SEPTEMBER 1992 ...
Page 42: ......
Page 72: ......
Page 102: ......
Page 110: ......
Page 144: ...INSTALLATION TELEPHONE SECTION 400 096 207 SEPTEMBER 1992 ...
Page 164: ......
Page 166: ...INSTALLATION PERIPHERALS SECTION 400 096 208 SEPTEMBER 1992 ...
Page 170: ......
Page 238: ...INSTALLATION WIRING DIAGRAMS SECTION 400 096 209 SEPTEMBER 1992 ...
Page 300: ......
Page 302: ...REMOTE ADMINISTRATION MAINTENANCE PROCEDURES SECTION 400 096 600 SEPTEMBER 1992 ...
Page 372: ......