Table 3.4.6 shows the parameter settings. Since these settings may greatly affect operation of the entire system,
the settings must be determined by taking the configuration of the entire PLC system into consideration. For
details of settings, see the instruction manual for parameters and actually set data.
Table 3.4.6 Transmission Parameter Settings
Data name
Application
Setting value
example
Explanation
0000 H
Not used
0400 H
TL-S20 standard version transmission
(ARND-8110)
2400 H
TL-S20 high-speed version transmission
(ARND-8110),
or PROFIBUS transmission (ARND-8130)
0020 H
TL-S20 standard version transmission
(ARND-8217)
$COMM_TYPE Transmission
mode selection
2020 H
TL-S20 high-speed version transmission
(ARND-8217)
0
Transmission not used
1 to 64
TL-S20 standard version transmission
$TL_SELF_NO
Own station No.
1 to 5
TL-S20 high-speed version transmission
0
Transmission not used
$TL_PC_NO
PLC station No.
Other
Master station number
3 to 31
TL-S20 standard version transmission
Transmission cycle target time (ms)
$TL_CYC_TIME Cycle
time
21
TL-S20 high-speed version transmission
6
Not using transmission between drive units
$SCAN_R_SIZE Number
of
receive words
setting
10
Using transmission between drive units
0
Transmission not used
0 to 1023
TL-S20 standard version transmission
$SCAN_R_ADRS
Start address of
receive data
0 to 127
TL-S20 high-speed version transmission
$SCAN_RCV01_AS Receiving
address 1
SERSEQDATA1,
SERSEQDATA2
Sequence signal (input)
* Usage is fixed
$SCAN_RCV02_AS
to
$SCAN_RCV06_AS
Receiving
address 2 to 6
Specifies data to
store received
data
When $SCAN_R_SIZE = 6 is set, 5 data can
be set freely.
When not used, Enter “DUST”.
R
e
ce
iv
ing w
o
rd dat
a
$SCAN_RCV07_AS
to
$SCAN_RCV10_AS
Receiving
address 7 to 10
Specifies data to
store received
data
Used to transmit data between drives
Data address of the opponent is specified as
$TL_OP_ST1 to 4 and $TL_OP_DT1 to 4
When not used, Enter “DUST”.
$SCAN_W_SIZE
Number of send
words setting
10
10 words are sent by scan transmission.
0
Transmission not used
0 to 1023
TL-S20 standard version transmission
$SCAN_W_ADRS
Start address of
send data
0 to 127
TL-S20 high-speed transmission
$SCAN_WR01_AS Sending
address 1
SSEQ_OUT1,
SSEQ_OUT2
Sequence signal (output)
* Usage is fixed
T
rans
mi
tti
ng w
o
rd
dat
a
$SCAN_WR02_AS
to
$SCAN_WR10_AS
Sending
address 2 to 10
Specifies data to
store received
data
When $SCAN_W_SIZE = 10 is set, 9 data
can be set freely.
When not used, Enter “DUST”.
0
Transmission not used
1 to 64
TL-S20 standard version transmission
$TL_OP_ST1
to
$TL_OP_ST4
Drive-to-Drive
transmission
opponent station
number
1 to 5
TL-S20 high-speed transmission
Driv
e-t
o
-driv
e
tr
ans
mi
ss
ion
$TL_OP_DT1
to
$TL_OP_DT4
Drive-to-Drive
transmission
opponent word
data address
Specifies data to
store received
data
4 data can be set freely.
When not used, Enter “DUST”.