2.3.10 Ratings
Tables 2.3.9, 2.3.10 and 2.3.11 list the ratings in the TMdrive-30 and TMdrive-P30 standard specifications.
Tables 2.3.12 and 2.3.13 list the ratings with over-load level in the TMdrive-30 and TMdrive-P30.
Table 2.3.9 TMdrive-30 Ratings Table (Standard Specifications)
Frame size
Output
capacity
[kVA]
DC voltage
[Vdc]
AC voltage
[Vac]
Rated
current
[Arms]
DC distribution
capability
[%] [Adc]
Generated loss
[kW]
1500 1500
693 70 686 18.5
2000 2000
924 70 914 24.5
3000 2×1500
2×693 70 2×686 37.5
4000 2×2000
2×900 1250
2×924 70 2×914 49.5
(Note) Generated loss is an approximate value.
Table 2.3.10 TMdrive-P30 Ratings Table (Standard Specifications)
Frame
size
Output
capacity
[kVA]
DC
voltage
[Vdc]
AC voltage
[Vac]
Rated input
current [Arms]
Rated output
current [Adc]
Generated
loss [kW]
Input power factor
2000
1700
2×900
1100V±10%
929
944
34
0.95 or more
4000
2×1700
2×900
1100V±10%
2×929
2×944
2×34
0.95 or more
Where, the rated input current is a value when
input voltage = 1100Vac
input power factor
= 0.98
Device efficiency = 0.98
The output capacity is a value when the input voltage is 1100 V ac or more. The output capacity when the input
voltage is below 1100Vac is as follows:
Output capacity [kW] = 1700 x (input voltage effective value) / 1100 Vac (See Figure Fig. 2.3.1).
85.5%
Output capacity
100%
95.5%
940V 1050V 1100V
1210V
Input voltage
Fig. 2.3.1 Relationship between input voltage and Output Capacity