— 100 —
6F3A4768
The display items are described below.
4.3.1 Equipment Model Name/Software Version Display
When power is turned on, the model name and the lower three digits of the software version are displayed.
(Inverter)
(Converter)
Fig. 4.3.4 Equipment Model Name/Software Version Display
4.3.2 Operation Data Display
When “READY” is established, operation data will be displayed. Each screen will be displayed cyclically at
3-second intervals.
Numerical display range: -999 to 999%
(Inverter)
(Converter)
Fig. 4.3.5 Operation Data Display
Equipment Model Name: TMdrive-30
“30”
Software version:
“01A”
To operation data display or
operation preparation display
Equipment Model Name: TMdrive-P30
“P30”
Software version:
“01A”
To operation data display or
operation preparation display
Speed Feedback
SP_F_DSP
When positive: “SP”
When negative: “SP-”
100% -100%
Primary Current Feedback
I1_F_DSP
100%
Output Power
MOT_POWER_PCT
When positive: “PO”
When negative: “PO-”
100% -100%
Primary Voltage Reference
E1_R_T
100%
Title
Numeric Value
Title
Numeric Value
Title
Numeric Value
Title
Numeric Value
DC Output Voltage
VDC_F_DSP
100%
Primary Current Feedback
I1_F_DSP
100%
Input Power
MOT_POWR_PCT
When positive: “PO”
When negative: “PO-”
100% -100%
AC Input Voltage
MAIN_VAC_F_FLT
100%