Table 2.3.14 Main Protective Functions of TMdrive-30
Detection *1
Linked operations *2
Major fault
Medium
fault
Minor
fault
Item Abbreviation
Hardware Software
Coast
stop
Dec
stop
Stop
request
Alarm
Related setting
AC overcurrent
OCA
Yes
Yes
$CP_OCA
DC overvoltage (P,N)
OVP, OVN
Yes
Yes
$CP_OV
DC overcurrent
OCD
Yes
Yes
CPU failure
CPU_A,CPU_M
Yes
Yes
Gate power supply failure GDM_F
Yes
Yes
External safety switch
UVS
Yes
Yes
Panel safety switch
P_SW
Yes
Yes
Phase fuse blown
F_U,V,W
Yes
Yes
Capacitor fuse blown
F_C
Yes
Yes
External interlock
IL
Yes
Yes
Transmission error
TL_F1~4
Yes
Yes
Overspeed
OSS
Yes
Yes
$CP_OSP
Speed detection error
SP_ERR
Yes
Yes
External equipment
electrical ready condition
UVA_EXT
Yes
Yes
(Yes)
Equipment ventilation fan
stop timer
C_FN_T
Yes
Yes
$TIME_CFAN
Control power source
failure
CPSF
Yes
Yes
$CP_PSF
Current limit timer
CL_T
Yes
Yes
$TIME_CL
DC voltage drop (P,N)
UVP, VVN
Yes
Yes
(Yes)
Overload (5 min)
OL5
Yes
Yes
(Yes)
$CP_RMS_5,
$CP_RMS_A
Overload (20 min)
OL20
Yes
Yes
(Yes)
$CP_RMS_20,
$CP_RMS_A20
Equipment overheat timer OH_T
Yes
Yes
$TIME_OH
Output open
AC_NL
Yes
Yes
Low frequency overload
STALL
Yes
Yes
Motor cooling fan stop
M_FN_T
Yes
Yes
$TIME_MFAN
Electromagnetic brake
energizing circuit fault
BR_F
Yes
Yes
$TIME_BR
Equipment overheat
OH
Yes
Yes
Motor cooling fan stop
M_FN
Yes
Yes
(Yes)
Current limit alarm
CL_TA
Yes
Yes
(Yes)
Equipment ventilation fan
stop
C_FN
Yes
Yes
(Yes)
Motor overheat
M_OH
Yes
Yes
(Yes)
Motor temperature
detector fault
MTMP_S
Yes
Yes
(Yes)
Overload alarm
OL_A
Yes
Yes
Motor overheat alarm
M_OH_A
Yes
Yes
Yes