3.4.4 DeviceNet Transmission Specifications
DeviceNet hardware specifications are shown in below.
Table 3.4.9 DeviceNet Hardware Specifications
DeviceNet transmission board type
Item
ARND-8127A
Connector type
Plug-in connector (open type)
Cable specification
Trunk line
One pair of twisted signal (#18):
Blue/White
One pair of twisted power source (#15):
Black/Red
Foil/stitch shielded drain wire (#18):
Open wire
Drop line
One pair of twisted signal (#24):
Blue/White
One pair of twisted power source (#22):
Black/Red
Foil/stitch shielded drain wire (#22):
Open wire
Depending on transmission speed
Transmission
speed [kbps]
Maximum trunk cable length
[m]
Maximum drop cable length
[m]
125
500 m
100 m
250
250 m
100 m
Transmission
distance
500
100 m
100 m
DeviceNet power
supply
24 V±1%