— 79 —
6F3A4768
3.4.7 Serial Input/Output Signals
3.4.7.1 Serial Input Signals
Table 3.4.21 shows examples of names of data to be input through the serial communication.
Table 3.4.21 Interface Data Examples (Input)
Data name
100%-count
Functions
SP_REF1
25000
Speed reference 1
SP_REF2
25000
Speed reference 2
SP_REFA1 25000
Auxiliary speed reference 1
TENS_R1
4000
Tension (Torque) reference 1
TENS_R2
4000
Tension (Torque) reference 2
Multiplied by coefficient in EXT_TENS_GAIN.
EXT_TENS_GAIN
10000/Gain 1 Load division ratio
Torque division ratio against the master is set.
IQ_LMT_EXT
4000
External current limitation value (torque limit)
SERSEQDATA1
Bit signal
Serial sequence command
SERSEQDATA2
Bit signal
Serial sequence command
DT_RD_SEQ
Bit signal
Serial sequence command
DT_DRV_SEQ
Bit signal
Drive-to-Drive transmission
This is used for receiving serial sequence output
(SSEQ_OUT1) of other drive.
DROOP_GAIN_T
10000
Drooping on-line gain
Value in $CR_DROOP_GAIN is set as initial
value.
ASPR_G_NO
0 to 3
Speed control gain selection command
This is valid only when $ASPR_G_SEL = 1.
ASPR_GAIN_EXT
100/Gain 1 When the speed control gain correction setting is
changed, this value is changed to newly set value
with rate.
StockCheck.com