— 66 —
6F3A4768
DeviceNet Master
PLC etc.
DeviceNet slave
Drive equipment
Address defined by
$SCAN_WR02_AS
BIT
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
BIT
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
SSEQ_OUT1
BLR
UVA
UV
READY
C_L
RNTD
FLDR
FD
RD
FAULT
ALARM
C_FN
CUT
SP_LMT
HB
Sequence output
UVA
C_L
RNTD
FLDR
C_FN
CUT
SP_LMT
UV
At Reference
Ref From Net
Ctrl From Net
Ready
Running 2 (Rev)
Running 1 (Fwd)
Warning
Faulted
Optional address defined by $SCAN_WR02_AS
Optional address defined by $SCAN_WR03_AS
Optional address defined by $SCAN_WR04_AS
Optional address defined by $SCAN_WR05_AS
Optional address defined by $SCAN_WR06_AS
Optional address defined by $SCAN_WR07_AS
Optional address defined by $SCAN_WR08_AS
Optional address defined by $SCAN_WR09_AS
Optional address defined by $SCAN_WR10_AS
Option1 Receive Data
Option2 Receive Data
Option3 Receive Data
Option4 Receive Data
Option5 Receive Data
Option6 Receive Data
Option7 Receive Data
Option8 Receive Data
Option9 Receive Data
ARND-8127
*1
*2
*1) Indifinite value (Do not use At
Reference)
*2) BIT 6: Net Ref of Command input
(See Fig. 3.4.11)
ex.) SSEQ_OUT1, 2, 4
Fig. 3.4.12
DeviceNet 4W/10W Mode (Send)