— 103 —
6F3A4768
4.3.7 Software Resetting Operation
Pressing “FAULT RESET” longer than 15 seconds in the Display mode when the electric condition (UV) is off
will set the Software Reset Operation screen following on the operations in 4.3.5 and 4.3.6.
In software resetting, initialize the system as in POWER-ON resetting while the power is turned on. By this,
setting changes that need initialization and initialization of the TOSLINE-S20 Transmission Option Boards
(ARND-8217) can be executed by panel operation without shutting down the power.
When stopping operation, release the button before counting down finishes.
Fig. 4.3.9 Software Resetting
Software reset start?
"rSt”
5 seconds before start
"St5”
4 seconds before start
"St4”
3 seconds before start
"St3”
2 seconds before start
"St2”
1 second before start
"St1”
0 second before start
"St0”
Software resetting execute
(Initializing)
"InI”
To Equipment model name/Software version
display
Countdown
StockCheck.com