DMC Status Code Key
Group 1 - DMC
Code
Message
Cause/Remedy
1-1
Plasma Disabled
Enable Plasma; Defective DMC Power Supply (E-Stop relay)
1-2
24 VDC fault
Check /replace DMC power supply fuse (F2); Replace DMC Power Supply; Replace DMC
control PCB
1-3
5 VDC fault
Check /replace DMC power supply; Replace DMC control PCB
1-4
No gas process selected
Select and send process from TSC 3000 or CNC;
1-5
DMC is locked
Process loading, wait until finished
1-6
Gas not Purged
DPC fault prevented purge from occuring, see DPC fault status
Group 2 - DPC Communication Port *
2-1
DPC Acknowledge error
Check DMC to DPC fiber optic cable and connections; Dirty or defective fiber-optic;DPC
power supply, fuse or Control PCB. DMC Control PCB
2-2
DPC Bus off error
Check DMC to DPC fiber optic cable and connections; Dirty or defective fiber-optic;DPC
power supply, fuse or Control PCB. DMC Control PCB.
2-3
Reserved
No information available; Contact customer service
Group 3 - CCM Communication Port *
3-1
CCM Acknowledge error
Check DMC to CCM fiber optic cable and connections; Dirty or defective fiber-optic;
Replace DMC Control PCB; Replace CCM.
3-2
CCM Bus off error
Check DMC to CCM fiber optic cable and connections; Dirty or defective fiber-optic;
Replace DMC Control PCB; Replace CCM.
3-3
Reserved
No information available; Contact customer service
Group 4 - Gas Controller Status and Protocal Errors
4-1
CCM Connection loss
Loss of communication with either DPC or DMC; check for dirty or defective fiber optic
to either DPC or CCM; See DPC and CCM status codes
4-2
CCM Timeout
Loss of communication with either DPC or DMC, check for dirty or defective fiber-optic
to either DPC or CCM. See DPC and CCM status codes.
4-3
DPC Timeout
Loss of communication with DPC, check for dirty or defective fiber-optic to DPC. See
DPC status code.
4-4
DPC error
Loss of communication with DPC, check for dirty or defective fiber-optic to DPC. See
DPC status code.
4-5
Reserved
No information available; Contact customer service
4-6
Reserved
No information available; Contact customer service
Summary of Contents for ULTRA-CUT 200 XT
Page 6: ...This Page Intentionally Blank...
Page 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Page 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Page 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Page 227: ......