ULTRA-CUT 200 XT
A-48
APPENDIX
Manual 0-5304
Art # 12301
1st INVERTER SECTION
(INV 1 A)
2nd INVERTER SECTION
(INV 1 B)
PILOT SW (IGBT)
WORK
(+)
TIP
ELECTRODE
(+)
The
AC Suppression PCB
has capacitors and other transient suppression components to protect the system from
transients on the AC lines. It also provides power for the neon AC present indicators which illuminate when AC
power is connected even when the ON-OFF switch, CB1, is off.
Differences between various models.
Auto-Cut 200, PAK200i and 300 XT units use the basic gas control/arc start circuits consisting of single gas inlets,
one for Plasma, one for Gas Shield. Also included with the Auto-Cut 300 XT and optional for the Auto-Cut 200XT
is a third inlet providing water for the H2O Mist shield.
There is a pressure regulator and gauge for each gas inlet and water flow meter/control when the H2O Mist option
is used. All 3 are turned on/off with control solenoids. Changing gas types requires connecting different gasses
to the rear panel and setting the gas switch on the rear panel to match the plasma gas type. There is no separate
pilot (Preflow) gas at this time.
The Auto-Cut 200 XT, Auto-Cut 300 XT and PAK200i Arc starter is the conventional spark gap type with water
cooled coil that we’ve used for several years. This arc starter injects the HF onto the torch electrode via the negative
lead with the return via the tip and pilot lead. The Ultra-Cut XT units use the remote arc starter, RAS 1000 XT. In
place of the spark gap the RAS 1000 XT uses a solid state ignition module to create the HF pulses which are injected
onto the tip and return via the electrode, the opposite direction of that used in the Auto-Cut, Auto-Cut XT and the
older RAS 1000 used with the Ultra-Cut units.
The
AC 200 XT
and PAK200i have the gas control and arc starter built into the main enclosure in the area that is used
for the top inverter module in other units of this family. The
AC 300 XT
has a separate gas control/Arc Starter that
sits on top of the main enclosure very similar to the GCM 1000 of our earlier Auto-Cut models. It is in fact called
a
GCM 1000 XT
. Both Auto-Cut XT and the PAK200i models have an analog current control (Potentiometer). On
the front panel of the main unit for the AC 200 XT and PAK200i and in the upper box, the GCM 1000 XT, for the AC
300 XT version. In either case the amperage setting is displayed on the front panel digital display.
Both Auto-Cut models have the gas mode switch on the rear, for the AC 300 XT next to the gas inlets of the GCM
1000 XT. On the AC 200 XT it’s near the connectors, fuses & circuit breakers. The switch should be set according
to the type of gas, AIR/O2 or N2, H35 or other non-oxidizing gas, being used for the plasma. The PAK200i does
not have this switch.
In the AC 200 XT and PAK200i, the Pilot board is mounted on the upper section of the second inverter module (IM#2)
the ½ module, in the place of the second or “B” section if it was a full module. The AC 300 XT and all Ultra-Cut XT
models have the Pilot board on the opposite side from the inverters, the “circuit breaker” side, in the upper rear be-
hind the CCM module. Refer to the Replacement Parts section of the manual for illustrations showing the locations.
Ultra-Cut XT units, 100, 200, 300 & 400A units all can use either the
GCM 2010
“manual” Gas control or the
DFC
3000 Auto Gas Control.
These gas controls remain unchanged from earlier Ultra-Cut units.
Ultra-Cut XT units use the same flow switch, FS1, as the Auto-Cut XT units to detect and prevent operation when
coolant flow is below the minimum of 0.75 GPM (2.8 l/m). However, the Ultra-Cut XTs include a coolant flow
sensor, FL1, which also measures the flow and can detect if there are gas bubbles in the coolant which can reduce
consumable part life. Detecting bubbles or low flow from FL1 will NOT prevent cutting but will show a code as a
warning that something is not right. The code is E406.
Summary of Contents for ULTRA-CUT 200 XT
Page 6: ...This Page Intentionally Blank...
Page 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Page 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Page 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Page 227: ......