ULTRA-CUT 200 XT
Manual 0-5304
INSTALLATION
3-19
!
CAUTION
Printed circuit boards in the Command - Control Module are static - sensitive. Discharge any
built-up static charges in your body or surroundings before touching the printed circuit boards.
SW-6: OK-to-Move: Contact closure, 120VAC @ 1A (Factory default setting) or
DC Volts (16-18vdc@ up to 100 ma.)
SW-11: Set “B” position, (up) for default
SW-11: Set “A” position (down) for remote analog current control. SW-8-2 must be set to “ON”.
SW-12-1/2/3/4: Divided Arc signal All = OFF = 50:1 (Factory default setting)
1 = ON = 16.6:1
2 = ON = 30:1
3 = ON = 40:1
4 = ON = 25:1
Art # A-12016_AB
Only 1 on at a time.
SW13: Ultra-Cut Switch positions
SW13
SW6
SW12
SW13 (Note positions 3-4 are not yet used)
1
2
3
4
ON
SW11