ULTRA-CUT 200 XT
Manual 0-5304
SPECIFICATIONS
2-5
2.09 Gas Requirements
The customer will provide all gases and pressure regulators. Gases must be of high quality. Pressure regulators shall be double
stage and installed within 3 meters from the Gas Console.
Ultra-Cut 200
XT™
Power Supply: Gas Pressures, Flows, and Quality Requirements
Gas
Quality
Minimum Pressure
Flow
O
2
(Oxygen)
99.5% Purity
(Liquid recommended)
120 psi
8.3 bar / 827 kPa
200 scfh (95 lpm)
N
2
(Nitrogen)
99.5% Purity
(Liquid recommended) <1000
ppm O
2
, <32 ppm H
2
O)
120 psi
8.3 bar / 827 kPa
200 scfh (95 lpm)
Compressed
or Bottled Air
Clean, Dry,
Free of Oil (see Note 1)
120 psi
8.3 bar / 827 kPa
450 scfh (212.4 lpm)
H35 (Argon-Hydrogen)
H35 = 35% Hydrogen,
65% Argon
99.995% Purity
(gas
recommended)
120 psi
8.3 bar / 827 kPa
200 scfh (95 lpm)
Ar (Argon)
99.995% Purity
(gas recommended)
120 psi
8.3 bar / 827 kPa
150 scfh (70.8 lpm)
H
2
O (Water)
See Note 2
55 psi (3.8 bar)
10 gph (0.6 lpm)
Note 1: The air source must be adequately filtered to remove all oil or grease. Oil or grease
contamination from compressed or bottled air can cause fires in conjunction with oxygen.
For filtering, a coalescing filter able to filter to 0.01 microns should be placed as close as
possible to the gas inlets on the Gas Control Module.
Note 2: The tap water source does not need to be deionized, but in water systems with extremely high mineral content a
water softener is recommended. Tap water with high levels of particulate matter must be filtered.
Note 3: Water Pressure Regulator No. 8-6118 is recommended to ensure proper water pressure.
2.10 Gas Applications
MATERIAL
MILD STEEL
STAINLESS STEEL
ALUMINUM
GAS TYPE
GAS TYPE
GAS TYPE
OPERATION PREFLOW PLASMA SHIELD PREFLOW
PLASMA
SHIELD PREFLOW PLASMA
SHIELD
30A Cut
Air
O
2
O
2
Air
Air
Air
Air
Air
Air
N
2
N
2
H
2
0
N
2
N
2
H
2
0
50A Cut
Air
O
2
Air
Air
Air
Air
Air
Air
Air
N
2
N
2
H
2
0
N
2
N
2
H
2
0
70A Cut
Air
O
2
Air
Air
Air
Air
Air
Air
Air
N
2
N
2
H
2
0
N
2
N
2
H
2
0
100A Cut
Air
O
2
Air
N
2
H35
N
2
N
2
H35
N
2
N
2
N
2
H
2
0
N
2
N
2
H
2
0
150A Cut
Air
O
2
Air
N
2
H35
N
2
N
2
H35
N
2
N
2
N
2
H
2
0
N
2
N
2
H
2
0
200A Cut
Air
O
2
Air
N
2
H35
N
2
N
2
H35
N
2
N
2
N
2
H
2
0
N
2
N
2
H
2
0
Marking
Air
Ar
Air/ O
2*
Air/ N
2*
Ar
Air/ N
2/
H
2
0
Air/ N
2 *
Ar
Air/ N
2/
H
2
0
*Note: Depends on process used.
Summary of Contents for ULTRA-CUT 200 XT
Page 6: ...This Page Intentionally Blank...
Page 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Page 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Page 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Page 227: ......