ULTRA-CUT 200 XT
Manual 0-5304
APPENDIX
A-81
406
Coolant Flow Low Warning
This code is a warning, it does not prevent cutting but if it persists the cause should be investigated. Ultra-Cut
XT units, in addition to a coolant flow switch, include a turbine flow sensor FL1, referred to in the plumbing
diagram as a “bubble sensor”, with a pulse output that accurately measures coolant flow and in addition can
detect the presence of gas bubbles in the coolant. Gas bubbles from leaking seals in the torch or hose fittings
have been proven to reduce consumable life. This code is a warning, it does not prevent cutting but if it persists
the cause should be investigated.
407
Coolant Overheated due to High Ambient
As described in the section for codes 259-264 the CCM measures the ambient temperature using sensor TS2 and,
like with the inverters, if the coolant is over temperature we first check the ambient and if it is above 40 deg C
we attribute the cause of the coolant over temperature to high ambient and of course the solution is to lower
the ambient or reduce the duty cycle.
The other possibility is the ambient measuring circuit is defective and the coolant is overheated. In that case
you would have to go to the section for code 403 to find the cause of the coolant overheating and go to section
for codes 259-264 to determine what is wrong with the TS2 circuit.
The 5 Group relates to CANBUS (Fiber optic) communication errors
501
CANBUS Failure to Acknowledge fault.
The CCM communicates with the gas controls (except GCM 1000 XT) over a fiber-optic cable using the CANBUS
protocol. The CCM is looking for a signal from the gas control (GCM 2010 or DMC) over the fiber-optic link.
No signal has been detected. Communication with the DPC which is relayed through the DMC sets a different
code, 301, if there is a problem with it.
Possible causes:
• Gas control is GCM 1000 XT (Auto-Cut 300XT) which has no fiber-optic, with Basic ID problem.
• CANBUS / Fiber-optic problem to either the GCM 2010 or the DMC (part of DFC 3000).
• Control Cable to DMC or GCM 2010 defective.
• Gas control (DMC or GCM 2010) main PCB blown fuse or defective.
• DMC power supply PCB blown fuse or defective.
• CCM defective.
Troubleshooting:
1. GCM 1000XT (also called a Basic Gas Control) does not use CANBUS (fiber-optic) communication. A jumper
in the gas control connector J56 pins 8 & 9, gives the signal “Basic ID” telling the CCM not to expect any
CANBUS. If somewhere this circuit is open, in the Gas Control cable, connector pins, connection from the
rear panel GCM connector, J55, to the CCM (J26) CCM will expect to see a CANBUS connection and report
this error because there is no CANBUS connected.
2. DFC 3000. If the gas control does not have power it will not communicate. Check for power to the gas
control boards.
a. When using Auto Gas (DFC3000) with DMC & DPC if there is no power to the DMC main board, the
green power light on the DMC front panel will not be lighted. The main board receives several voltages
from its separate power supply board. For communication it needs +5VDC. There is a green LED, D17
(first on the left of the row of LEDs.) that lights when the main board has +5V power.
b. The DMC power supply board has several blue LEDs that light when it has power. If none of these are
on check for the control cable being connected or the circuit breaker, CB2, on the plasma supply rear
panel may be tripped in which case there is probably a short somewhere.
c. The DMC power supply which supplies several voltages could be missing one or more and still have
some blue LEDs lighted. Check for voltages.
Summary of Contents for ULTRA-CUT 200 XT
Page 6: ...This Page Intentionally Blank...
Page 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Page 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Page 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Page 227: ......