ULTRA-CUT 200 XT
A-52
APPENDIX
Manual 0-5304
Plasma Enable from Gas Control or TSC 3000
If the External or CNC Plasma Enable is satisfied, D2 is on, a relay K7 on the CCM I/O PCB energizes supply-
ing +15V to another relay K1 on the I/O board. An active low signal, /Plasma Enable-HMI, comes from TSC
3000 Plasma Enable switch via the Relay PCB or if TSC 3000 is not installed the signal originates on the Relay
PCB. This signal applies ground to the K1 relay energizing it and lighting the LED, D3 on the I/O board. K1’s
contacts go back to the Relay board and the Gas control connector J55 to allow turning on relays and solenoids
on those devices. The AC 200 XT does not use the separate Gas Control or the TSC 3000.
Art # 12304
1
5
3
2
4
K7
1
8
4
2
6
7
3
5
PLASMA ENABLE
K1
/PLASMA ENABLE - HMI
GND
24 VAC
24 VAC
TSC 3000
RELAY PCB
1
5
3
2
4
PLASMA ENABLE - CNC
K6
+15VDC
GREEN
D3
PS_ENABLE
To
Relay
PCB
To Gas
Control
CCM I/O PCB
GREEN
D2
Plasma Enable SW
GCM 2010
(or jumper in
other gas controls)
-1
-3
-5
-6
J54
J55
XT Power Supply
Simplified schematic, all connectors are not shown.
Refer to unit schematics for details.
J61
J56
-1
-2
Jumper in
AC 200 XT
J26-6
J26-7
GCM 1000 XT
J56
J54
When the circuit between J54-1 & 3 is closed (jumper,
etc.) K7 is energized and requires a Plasma Enable SW
or equivlant to enable the plasma.
With J54-1 & 3 open K7 is denergized and it's NC
contacts complete the Plasma Enable-HMI circuit.
-1
-2
-2
-1
-5
-6
-3
-1
-5
-6
-3
-1
(AC 300 XT
DMC 3000)
J25
-15
-22
J30
-20
-25
Plasma
Enable
SW
iCNC
XT 2 &
XT 242
J54
-5
-6
-3
-1
iCNC
XT 211
HMI PLASMA
ENABLE BYPASS
If a TSC 3000 is not connected or unit is an Auto-Cut, K7 on the Relay PCB is de-energized and GND is con-
nected through its normally closed contacts. If the TSC is connected, 24 VAC through a jumper in the TSC 3000
energizes K7, opening its NC contacts and now GND connects through the TDC 3000 Plasma Enable switch.
The GND obtained by either path passes through the GCM 2010 Plasma Enable switch or through a jumper
(J56-1 to J56-2) present in the other gas controls (GCM 1000 XT or DMC 3000) and is connected to the coil of K1
on the I/O PCB. If the CNC Plasma Enable is also active (D2 is on) +15V will be connected to K1’s coil through
the relay K7 on the I/O PCB. This energizes K1 and turns on D3, Plasma Enable LED. The contacts of K1 go
back to the Relay board and to the Gas control to enable power to connect to relays and solenoids in those items.
Troubleshooting:
1. If both D2 and D3 are on and you still have 101 fault replace the CCM. Otherwise go to step 2 except if
it’s an AC 200 XT skip to step 4.
2. If D3 is not on and there is a TSC 3000 in use remove its cable from J54. K7 on the Relay board will de-
energize and satisfy the Plasma Enable to K1. If D3 is now on problem was in the TSC 3000 or its cable.
Otherwise reconnect the cable.
3. For an Ultra-Cut with DFC 3000 or GCM 2010 or an Auto-Cut 300 with a GCM 1000 XT remove the cable
from J55 the gas control connector and jumper pins 1 & 2. If D3 is on now problem is in the Gas Control
or its cable. If D3 still not on replace the Gas Control cable.
4. If neither of the above steps works, on the CCM I/O board, jumper J26-7 to GND (TP1 on I/O). If D2 is
on and D3 still does not light then replace the CCM.
5. If D3 does light in the above step find the 40 pin ribbon cable plugged in to the top of the CCM. Confirm
that it is plugged in to both the CCM and the Relay board and the connector tabs are locked in place.
Now using the spare receptacle measure voltage between GND (TP1 on I/O) and the ribbon cable pin 12.
It should be zero V. If not, if it’s something like 10-15VDC, the ribbon cable is open or the Relay board
is defective.
Summary of Contents for ULTRA-CUT 200 XT
Page 6: ...This Page Intentionally Blank...
Page 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Page 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Page 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Page 227: ......