5. Connect Control cable from the Power Supply to J56 on the front of the DMC-3000 as shown below. The Fiber Optic cable
will be covered a little later.
Art # A-09142_AB
6. Install WMS Water Softener Kit in the line that feeds the inlet side of the DMC-3000. Mount the softener and bracket on
the power supply where the provided 2’ hose can reach to the DMC-3000. Mounting in another location is possible with
a customer provided hose. Below is typical customer added hose and installation.
Art # A-09655
7. Make sure that the hose going to the DMC-3000 is connected to the port on the WMS Water Softener marked “OUT” and
the incoming water supply connected to the port marked “IN”. Do not mount over any electronics or outlets in case of
leaks during operation or spills when changing the element at a later date.