CCM Status Code
Group 2 -- Plasma Power Supply
Code
Message
Remedy / Comments
229
Inverter 3A Incompat-
ible Revision
Unsupported Inverter Revision; Ribbon cable CCM J35 to Inverter Module 3 Section
A damaged; CCM code version incompatible with Inverter revision or model
230
Inverter 3B Incompat-
ible Revision
Unsupported Inverter Revision; Ribbon cable CCM J36 to Inverter Module 3 Section
B damaged; CCM code version incompatible with Inverter revision or model
231
Inverter 1A VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J31 to Inverter Module 1 Section A; Wrong voltage
Inverter Module 1 installed; Defective Inverter module
232
Inverter 1B VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J32 to Inverter Module 1 Section B; Wrong voltage
Inverter Module 1 installed; Defective Inverter module
233
Inverter 2A VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J33 to Inverter Module 2 Section A; Wrong voltage
Inverter Module 2 installed; Defective Inverter module
234
Inverter 2B VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J34 to Inverter Module 2 Section B; Wrong voltage
Inverter Module 2 installed; Defective Inverter module
235
Inverter 3A VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J35 to Inverter Module 3 Section A; Wrong voltage
Inverter Module 3 installed; Defective Inverter module
236
Inverter 3B VAC
Mismatch
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J36 to Inverter Module 3 Section B; Wrong voltage
Inverter Module 3 installed; Defective Inverter module
237
Too Few Inverters
Found
Two or more Inverter Sections required to operate; Ribbon cable from CCM to
Inverter Section damaged or disconnected;
238
BIAS VAC Invalid
Invalid AC Voltage Selection; Damaged or loose connection at J61 of System Bias
Supply; Defective System Bias PCB
239
AC Voltage High
System Bias PCB detected AC Voltage is higher than Power Supply rated Voltage;
System Bias Supply J61 Voltage Selection connection damaged or disconnected;
Defective System Bias PCB; Defective CCM
240
AC Voltage Low
System Bias PCB detected AC Voltage is lower than Power Supply rated Voltage;
System Bias Supply J61 Voltage Selection connection damaged or disconnected;
Defective System Bias PCB; Defective CCM
241
Inverter 1A Input Volt-
age Error
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-
verter Module 1 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or
open connection between input terminals and W1 contactor or contactor and input
of Inverter Section; Defective Inverter module
242
Inverter 1B Input Volt-
age Error
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-
verter Module 1 Section B; Poor AC Power Quality; Defective W1 contactor; Loose or
open connection between input terminals and W1 contactor or contactor and input
of Inverter Section; Defective Inverter module
243
Inverter 2A Input Volt-
age Error
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-
verter Module 2 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or
open connection between input terminals and W1 contactor or contactor and input
of Inverter Section; Defective Inverter module
244
Inverter 2B Input Volt-
age Error
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-
verter Module 2 Section B; Poor AC Power Quality; Defective W2 contactor; Loose or
open connection between input terminals and W2 contactor or contactor and input
of Inverter Section; Defective Inverter module
Summary of Contents for ULTRA-CUT 200 XT
Page 6: ...This Page Intentionally Blank...
Page 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Page 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Page 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Page 227: ......