3-17
!
CAUTION
Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being
forced into tight-radius turns.
2. Remove outer thin nut from through hole protector at one end of Fiber Optic Cable (L) that connects between the CCM
portion of the Power Supply and the DMC-3000.
3. Feed the Fiber Optic Cable plug and wires through the hole where the plastic plug was removed labeled GCM/DMC and
slide the thin nut back over the Fiber Optic Cable.
4. Secure the thin nut on the through hole protector so both nut faces are tight against the sheet metal inside and out.
5. Plug the Fiber Optic Cable into the PCB as shown below. Make sure the locking tabs are engaged. Fiber Optic for the
DMC-3000 goes into the lower pair of fiber optic receptacles (U31 & U37).
Art # A-11998
Fiber Optic
Cable
Plug
Thin nut securing
the through hole
protector