ULTRA-CUT 200 XT
Manual 0-5304
OPERATION
4-25
Group 5 - Shorted Solenoid Faults
5-1
Sol 1 – H35 Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-2
Sol 2 – Oxygen Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-3
Sol 3 – Air Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-4
Sol 4 – Nitrogen Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-5
Sol 5 – Aux Plasma
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-6
Sol 6 – Oxygen Shield
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-7
Sol 7 – Air Shield
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-8
Sol 8 – Nitrogen Shield
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-9
Sol 9 – H2O Shield
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-10
Sol 10 – Oxygen Preflow Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-11
Sol 11 – Air Preflow
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-12
Sol 12 – Nitrogen Preflow Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-13
Sol 13 – Argon Marking
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-14
Sol 14 – Air Marking
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
5-15
Sol 15 – Nitrogen Mark-
ing
Replace solenoid; Shorted wire harness; Defective DMC Control PCB
* Communication faults shown on the DMC can be caused by the device on the other end of the communication line.
Before assuming the DMC is at fault see if either the CCM or the DPC are showing any codes that might indicate they are at
fault instead.
4.13 DPC-3000 Status Codes
DPC Status Code Key
Group 1 - DPC
Code
Message
Cause/Remedy
1-1
Plasma Disabled
Enable Plasma; DMC Power Supply input fuse F1 blown (no lights on DMC); Defective DMC
Power Supply (E-Stop relay). Defective DPC Power Supply (E-Stop relay). Defective DPC control
PCB
1-2
24 VDC fault
Check /replace DPC power supply output fuse (F2); Defective DPC power supply; Replace DPC
control PCB
1-3
+12 VDC fault
Check /replace DPC power supply; Replace DPC control PCB
1-4
-12 VDC fault
Check /replace DPC power supply; Replace DPC control PCB
1-5
5 VDC fault
Check /replace DPC power supply; Replace DPC control PCB
1-6
Analog Reference fault
Replace DPC Control PCB
1-7
ADC voltage fault
Replace DPC Control PCB
1-8
Reserved
1-9
Valve not configured
Resend process from TSC 3000 / CNC
1-10 DPC is locked
Process loading, wait until finished
Group 2 - Control Communication
2-1
Acknowledge error
Fiber optic cable; DPC Control PCB
2-2
Timeout
Communication loss: Check DMC codes; if DMC 2-1 check DPC to DMC Fiber optic cable, DMC
4-2 check DMC to CCM fiber-optic cable.; DPC Control PCB; DMC Control PCB; CCM.
2-3
Protocol
Program firmware fault, consult factory
2-4
Bus off
Fiber optic cable; DPC Control PCB
2-5
Physical
Fiber optic cable; DPC Control PCB
Summary of Contents for ULTRA-CUT 200 XT
Page 6: ...This Page Intentionally Blank...
Page 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Page 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Page 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Page 227: ......