3. Check for 230 VAC at either of the fan connectors, J72 & J73. It may also be measured at the rear panel con-
nector J70 for the HE400XT fan.
a. If the fans are not getting 230 VAC, measure for 24 VAC on the coil of MC2. If present and the relay
contacts aren’t closed the relay is defective. Note, the coil is rectified so you won’t measure continuity
of even a good coil.
b. If 24 VAC is not on the MC2 coil check for D24 on the relay board being ON. If it’s on, the Relay board
should be providing the 24 VAC so if it’s not the Relay board must be defective.
c. If D24 is not on, measure on the CCM I/O board between TP2 and the common at TP1. It should be low,
near zero volts. If not the CCM is probably defective. Jumper TP2 (I/O board) to TP1. If the fans now
come on replace the CCM.
d. If jumping TP2 to TP1 does not turn the fans on then the Relay board or the 40 pin ribbon cable pin 19
is at fault.
404
Coolant System Not Ready
When power is applied to the system with External Plasma Enable satisfied and Plasma Power Supply Enabled
(switch on 2010 or TSC 3000), assuming there is enough coolant in the tank, after some initial tests taking about
15-20 seconds (see manual section 4 for details of the Start-Up Sequence) the pump will start. Coolant will be
pumped through the system. Flow is measured by the FS1 flow switch placed in the torch coolant return path
just before the radiator (see plumbing diagram). If the flow doesn’t reach at least 0.75 GPM (2.8 lpm) within
4 minutes it will set the 404 fault. The reason for the 4 minutes is a new dry system especially one with long
torch leads will take some time before the leads, hoses, radiator and cold plates are full of coolant. More coolant
may have to be added. On a system that has been run before it normally takes only a few seconds to establish
proper flow. In any case the pump will run for 4 minutes before setting the 404 fault.
First determine if the pump motor is running and if so is there any coolant flowing. With the right lower side
panel removed touch the pump and feel for vibration to indicate if the motor is running. Observe the clear
coolant hoses to see if they are full of coolant. There are two hose fittings on the back of the tank. The upper
one is the coolant return. Remove the tank filler cover. You should see a fairly strong stream of coolant from
that fitting. The lower fitting is from the pump bypass valve. If the pump is operating some coolant may be
exiting that fitting as well. If these fittings are below the coolant level you may have to drain out some of the
coolant to see this. If a strong stream is exiting the bypass (lower) fitting but nothing from the upper fitting,
you probably have some kind of blockage.
Reasons for 404 faults (Coolant not flowing):
• In new installation, coolant has not circulated all the way through the leads. Add more coolant if neces
-
sary and recycle the power to restart the pump and 4 minute timer.
• Coolant supply & return leads are reversed, check valve in torch coolant return prevents reverse flow.
• Torch parts removed or are wrong style so torch check valve shuts off flow.
• Torch coolant tube damaged or the tube extension (if required) missing.
• No power to pump motor.
• Pump/motor failure.
• Bypass valve defective or adjusted incorrectly.
Summary of Contents for ULTRA-CUT 200 XT
Page 6: ...This Page Intentionally Blank...
Page 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Page 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Page 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Page 227: ......