APPENDIX 28: SL100 Torch Option
Preparations for Operation
NOTE!
Automated and manual plasma cutting cannot be performed at the same time. The 1Torch trigger is
ignored when automation cutting is in process, and XT start signal is ignored during hand cutting.
Operators must wait until postflow is complete before cutting with the alternate torch
At the start of each operating session:
WARNING
Disconnect primary power at the source before assembling or disassembling power
supply, torch parts, or torch and leads assemblies.
Torch Connections
If necessary, connect the torch to the Power Supply. Connect only the Thermal Dynamics model SL100 Manual
Torch to this power supply. Maximum torch leads length is 100 feet / 30.5 m, including extensions.
1. Align the ATC male connector (on the torch lead) with the female receptacle. Push the male connector into
the female receptacle. The connectors should push together with a small amount of pressure.
2. Secure the connection by turning the locking nut clockwise until it clicks. DO NOT use the locking nut to
pull the connection together. Do not use tools to secure the connection.
2
Art # A-12761
Connecting the Torch to the Power Supply
Summary of Contents for ULTRA-CUT 200 XT
Page 6: ...This Page Intentionally Blank...
Page 15: ...ULTRA CUT 200 XT Manual 0 5304 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 28: ...ULTRA CUT 200 XT SPECIFICATIONS Manual 0 5304 This Page Intentionally Blank...
Page 76: ...ULTRA CUT 200 XT INSTALLATION Manual 0 5304 This Page Intentionally Blank...
Page 160: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 17 Cap Bias Bottom PCB Layout Art A 11685_AB...
Page 162: ...ULTRA CUT 200 XT APPENDIX Manual 0 5304 APPENDIX 19 Suppressor PCB Layout Art A 11684_AB...
Page 165: ...ULTRA CUT 200 XT Manual 0 5304 APPENDIX A 39 This Page Intentionally Blank...
Page 227: ......