1
Wire Repair Kit
Globally Proven
Construction Solutions
Globally Proven
Construction Solutions
Tools & Items Required for Repair
1. One Repair kit consisting of:
2x Large heat shrink
12x Small heat shrink
12x Small butt crimp
1x Length of bridge wire
2. Crimping Tool
3. Heat gun
4. Stanley knife / Wire strippers
5. Side cutters
6. Multimeter
Testing of the Heater During and After Repair
Do not tile if the heater does not pass all the tests.
There may be a problem with new joint or additional wire breaks.
Actual value should be +/-5%.
Contact LATICRETE at 1-800-243-4788 for further assistance.
120V Model
Resistance
0802-0017-2
221.5
0802-0034-2
110.8
0802-0050-2
73.8
0802-0067-2
55.4
0802-0084-2
44.3
0802-0100-2
36.9
0802-0133-2
27.4
0802-0166-2
22.0
0802-0200-2
18.3
0802-0233-2
15.6
0802-0266-2
13.7
0802-0299-2
12.2
0802-0332-2
11.0
0802-0365-2
10.0
0802-0398-2
9.1
240V Model
Resistance
0802-0083-4
177.2
0802-0100-4
147.7
0802-0133-4
109.7
0802-0166-4
87.9
0802-0200-4
73.4
0802-0233-4
62.6
0802-0266-4
54.9
0802-0299-4
48.8
0802-0332-4
44.0
0802-0415-4
35.1
0802-0498-4
29.2
0802-0581-4
25.0
0802-0664-4
21.9
0802-0747-4
19.5
0802-0830-4
17.8
STRATA_HEAT
™
Wire Systems
Warranty Disclaimer:
This guide and the repair kit included have
been provided by LATICRETE, Inc. to aid in the repair of STRATA_HEAT™ Wire
systems damaged on-site. LATICRETE cannot warranty the repair or guarantee
the proper function of the heating system following a repair. LATICRETE
recommends that all repair work be carried out by a qualified electrician and
conform with current IEE Wiring Regulations.
For any further assistance, please contact LATICRETE at 1-800-243-4788.
CAUTION:
Before commencing with the repair, ensure that the heating
system has been completely disconnected from the power source.
ADVANCED FLUOROPOLYMER INSULATION
MULTI-STRAND
TWIN CONDUCTORS
GROUND BRAID
Heating Wire Construction
On-Site Repair Kit Guide
On-Site Repair Kit Guide for STRATA_HEAT
™
Wire Systems