background image

Prepared by KM 11/2015 

                                                                               1                                                                                        Patent pending 

14407 Coil Plus Dr, Unit A | Plainfield, IL 60544 
www.sennco.com | [email protected] 

815.577.3400 | Toll free 866.736.6261 

Mon - Fri 9AM - 5PM CST 

 

Instructions for Wireless Security System 

Power & Alarm Solution 

(Code 120-001)  Rev 4 

Summary of Contents for 150001

Page 1: ...t pending 14407 Coil Plus Dr Unit A Plainfield IL 60544 www sennco com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST Instructions for Wireless Security System Power Alarm Solution Code 120 001 Rev 4 ...

Page 2: ...peration of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement P...

Page 3: ...age 9 III Set Up Where do I put these A Cradles Page 10 B Main alarm Page 12 C Sniffer Page 12 D Gateway Page 12 E Bubble makers Page 13 F Sensor heads Page 14 G Connecting sensor heads to cordwinder cables Page 15 H Disconnecting sensor heads from cordwinder cables Page 15 IV Teaching DaKeys How do I program the DaKey A Teaching the first DaKey Page 16 B Teaching additional DaKeys Page 16 V Confi...

Page 4: ... 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST I Parts List DaKey Main alarm unit AC power cable for main alarm A Main alarm Bubble maker AC power cable for bubbler maker B Bubble maker Sniffer AC power cable for Sniffer D Sniffer C Sensor head Sensor head shielding Sensor head Sensor head adhesive WPWR cable Key ...

Page 5: ...d IL 60544 www sennco com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST E Cradle Cordwinder 7 Adhesive for Cordwinder 7 F Gateway Cradle mounting plate Cradle AC power cable Bolts with T nuts Gateway AC power cable Gateway antennas WLAN 3G GPRS ...

Page 6: ...ing 14407 Coil Plus Dr Unit A Plainfield IL 60544 www sennco com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST II Description of Alarm Button LCD DIP switches Antenna AC power port DaKey port A Main alarm ...

Page 7: ...com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST Antenna AC ower port Plunger switch B Bubble maker DIP switches Antenna internal Arrow all bubble makers must face the same direction C Sensor head Micro USB charging port Cordwinder cable end port Charging contacts ...

Page 8: ...l Plus Dr Unit A Plainfield IL 60544 www sennco com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST Antenna AC ower port Plunger switch D Sniffer Antenna AC power port E Cradle Charging contacts AC power port USBA cable ...

Page 9: ...pending 14407 Coil Plus Dr Unit A Plainfield IL 60544 www sennco com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST F Gateway USB port WLAN antenna port taller 3G GPRS antenna port shorter AC power port ...

Page 10: ...urn the bolts clockwise until tightened down 5 The slot in the center post of the cradle mounting plate should be open at the top and the large opening in the cradle mounting plate should be at the top left 6 Find the cordwinder Clean the top of the cordwinder box where the cable exits using an alcohol wipe Dry it with a clean cloth 7 Peel the backing off of the cordwinder mounting adhesive and se...

Page 11: ...e cradle mounting plate 13 Plug the cable into the power port on the bottom of the cradle 14 Guide the cable into the cable keeper 19 There is a red LED on the bottom of the cradle which will be lit when the cradle is receiving power This LED is not visible when the cradle is on the cradle mounting plate 20 Repeat as necessary for additional cradles 15 Make sure that the mouse hole is towards the ...

Page 12: ... C Sniffer 1 Plug the barrel plug end of the AC power cable into the AC power port on the sniffer 2 Plug the other end of the cable into an outlet that has AC power available 3 Place the sniffer in a secure location within 50 feet of the system with the antenna positioned vertically 90 D Gateway 1 Screw the taller antenna into the left position labeled WLAN and the shorter antenna into the right p...

Page 13: ...of the cable into an outlet that has AC power available 3 The green LED on the front of the bubble maker indicates power is being received 4 Place the bubble maker in position Note They cannot be placed upside down a Each bubble maker generates a 6 ft 8 ft radius sphere within which the protected devices are safe b Additional bubble makers should be spaced 3 1 2 feet apart c Each bubble maker has ...

Page 14: ...thed down and securely adhered across the inside face of the sensor head F Sensor heads 5 Peel the backing off of one side of the sensor head adhesive 6 Secure the adhesive to the sensor head on top of the shielding Press firmly for about 15 seconds for a strong adhesive bond 7 Place the sensor head on a powered cradle to wake up the sensor head 8 Two red LEDs on the back of the sensor head will f...

Page 15: ...cable end into the hole in the back of the sensor head Then turn the cable end a quarter turn clockwise You will hear and feel a click when the cable is locked 3 The cable end will still rotate about a quarter turn but will not come out without using the cable release key H Disconnecting sensor heads from cordwinder cables 1 Insert the cable release key into the hole in the side of the sensor head...

Page 16: ...be taught to the system IV Teaching DaKeys DaKeys will be programmed or taught to the system simply by inserting them into the DaKey port on the main alarm The first DaKey inserted will be taught automatically Additional DaKeys can be taught by inserting them within five seconds after removing a previously taught DaKey Anytime a recognized DaKey is inserted and removed the system provides a five s...

Page 17: ...state DISARMED E Hold down the button on the front of the main alarm for 4 seconds F The LCD will state CONFIGURING and show a device count of 000 G The bubble makers will all begin to ping a signal back to the main alarm indicated by a blue flashing LED on each bubble maker H The main alarm will listen for all of the sensor heads and the device count on the LCD will be updated I When completed th...

Page 18: ...hing red LEDs will cease The sensor head will return to flashing green LEDs indicating it is armed E If however the device is not returned to the safe zone within 10 seconds then the main alarm will be triggered causing it to emit a loud alarm that is audible throughout the area VII Silencing the Main Alarm A If the system alarms check the LCD on the main alarm It will show which sensor head has t...

Page 19: ...vice or from the sensor head or if it is cut then the main alarm will immediately be triggered If the sensor head is removed from the back of the protected device then the main alarm will immediately be triggered If the sensor head is outside of the safe zone created by the bubble makers for more than 10 seconds then the main alarm will be triggered IX Hard Reset The entire system can be reset by ...

Page 20: ...l Plus Dr Unit A Plainfield IL 60544 www sennco com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST Questions Please contact Sennco Solutions technical support at Toll free phone 866 736 6261 Email techsupport sennco com ...

Page 21: ...Prepared by KM 11 2015 21 Patent pending 14407 Coil Plus Dr Unit A Plainfield IL 60544 www sennco com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST Notes ...

Page 22: ...Prepared by KM 11 2015 22 Patent pending 14407 Coil Plus Dr Unit A Plainfield IL 60544 www sennco com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST Notes ...

Page 23: ...d by KM 11 2015 23 Patent pending 14407 Coil Plus Dr Unit A Plainfield IL 60544 www sennco com techsupport sennco com 815 577 3400 Toll free 866 736 6261 Mon Fri 9AM 5PM CST This page intentionally left blank ...

Reviews: