89
98-05304-EN R2
Aeros 9040 field computer
HOME
SE
TUP
FULL SCREEN
IMPLEMENT
INTR
ODUC
TION
GNSS
RA
TE C
ONTR
OL
APPENDIX
GUID
ANCE
With an ISOBUS implement status module (ISO ISM)
All ISOBUS rate control configurations should be setup before
starting BoomPilot. Regulation mode should be “Manual”.
To set configuration settings:
1. Press SYSTEM SETUP bottom tab
.
2. Press CONFIGURATION side tab
.
3. Press
Implement
.
4. Set “BoomPilot icon” to
Enable
.
NOTE: BoomPilot start mode setting will make no difference in the
function of this option.
To switch application off or on automatically:
1. Press NAVIGATION AND GUIDANCE OPTIONS tab
to
display navigation options.
2. Press BOOMPILOT icon .
◄Automatic – status bar icon will change to green
NOTE: Application can be manually controlled while in Automatic
BoomPilot mode using the switches connected to the
ISO ISM.
To switch application off or on manually:
1. Press NAVIGATION AND GUIDANCE OPTIONS tab
to
display navigation options.
2. Press BOOMPILOT icon .
◄Automatic – status bar icon will change to red
3. Turn master switch or individual section switches On/Off.
ISOBUS spreader
If an ISOBUS electronic control unit (ECU) is present, the
BoomPilot icon or an optional remote master switch can be used to
turn the application on or off. The BoomPilot icon may also be used
to set automatic section control to manual or automatic .
NOTE: The BOOMPILOT icon is grey
when GNSS is
unavailable.
Console only
All ISOBUS rate control configurations should be setup before
starting BoomPilot. Regulation mode should be “Manual”.
To set configuration settings:
1. Press SYSTEM SETUP bottom tab
.
2. Press CONFIGURATION side tab
.
3. Press
Implement
.
4. Set “BoomPilot icon” to
Enable
.
NOTE: BoomPilot start mode setting will make no difference in the
function of this option.
To switch application off or on automatically:
1. Press NAVIGATION AND GUIDANCE OPTIONS tab
to
display navigation options.
2. Press BOOMPILOT icon .
◄Automatic – status bar icon will change to green
3. Press the ISOBUS UNIVERSAL TERMINAL bottom tab
.
4. Go to the Operation screen.
5. Use the START/STOP key .
NOTE: Application can be manually controlled while in Automatic
BoomPilot mode using the Start/stop key on the ISOBUS
Operation screen.
To switch application off or on manually:
1. Press NAVIGATION AND GUIDANCE OPTIONS tab
to
display navigation options.
2. Press BOOMPILOT icon .
◄Automatic – status bar icon will change to red
3. Press ISOBUS UNIVERSAL TERMINAL bottom tab
.
4. Go to the Operation screen
5. Use the START/STOP key .
With optional spreader on/off switch
All ISOBUS rate control configurations should be setup before
starting BoomPilot. Automatic or manual regulation mode should not
affect the following options.
To set configuration settings:
1. Press the ISOBUS UNIVERSAL TERMINAL bottom tab
.
2. Enable the Remote spread switch.
3. Press SYSTEM SETUP bottom tab
.
4. Press CONFIGURATION side tab
.
5. Press
Implement
.
6. Set “BoomPilot icon” to
Disable
.
NOTE: BoomPilot start mode setting will make no difference in the
function of this option.
In areas where application is desired:
1. Turn Spreader on/off switch to the “on” position.
In areas where application is not desired:
1. Turn Spreader on/off switch to the “off” position.
Summary of Contents for AEROS 9040
Page 1: ...Software version 4 31 U S E R M A N U A L AEROS 9040...
Page 116: ......