65
98-05304-EN R2
Aeros 9040 field computer
HOME
SE
TUP
GUID
ANCE
FULL SCREEN
INTR
ODUC
TION
GNSS
RA
TE C
ONTR
OL
APPENDIX
IMPLEMENT
NOZZLE SELECTION
When the system includes a Pressure sensor interface kit (PSIK),
Nozzle selection is used to select the type of sprayer nozzle (series
and capacity) for determining droplet size information.
1. Press CONFIGURATION side tab
.
2. Press
Implement
.
◄Current nozzle section is shown in the information box
3. Press Nozzle selection NEXT PAGE arrow
.
4. Select from:
►Nozzle preset 1-5 – selects up to five (5) tips for quick recall,
and selected the current nozzle for determining droplet size
information
►Current nozzle – displays the current nozzle
5. Press RETURN arrow or CONFIGURATION side tab
to
return to the main Configuration screen.
Figure 6-41: Droplet size monitor
Preset
Nozzle presets allow saving of up to five tips for quick recall.
1. Press
+
.
2. Select a TeeJet nozzle series.
3. Select nozzle capacity.
Figure 6-42: Preset nozzle
Nozzle sizes and associated colours
Established Nozzle Capacities and Colours
Size
Color
Size Color
01
Orange
06
Grey
015
Green
08
White
02
Yellow
10
Light Blue
025
Purple
12
Telemagenta
03
Blue
15
Light Green
04
Red
20
Black
05
Brown
30
Beige
Summary of Contents for AEROS 9040