75
98-05304-EN R2
Aeros 9040 field computer
HOME
SE
TUP
FULL SCREEN
IMPLEMENT
INTR
ODUC
TION
GNSS
RA
TE C
ONTR
OL
APPENDIX
GUID
ANCE
STATUS BAR
The Status bar provides information on GNSS status, guidance
mode, exterior boundary area, assisted/auto steering engagement,
tilt correction, implement control status, droplet/pressure status, and
nozzle flow status.
When an icon is pressed, the related status information is displayed.
Figure 7-5: Status bar
Tilt correction status
BoomPilot status
Droplet/pressure status
Nozzle flow status
GNSS status
Guidance mode
Exterior bounded area status
Assisted/auto steering status
GNSS status
Green = GPS, GLONASS, or SBAS (with or without DGPS
Required)
Yellow = GPS only
Red = no GNSS
Orange = Glide/ClearPath
Guidance mode
No icon = no guidance
Straight AB guidance
Curved AB guidance
Circle pivot guidance
Last pass guidance
NextRow guidance
Adaptive curve guidance
Bounded area status
Outside exterior boundary = traveling outside exterior
bounded area
Inside exterior boundary = traveling inside exterior bounded
area
No icon = no boundary established (exterior or interior)
Assisted/auto steering status
Green = engaged, actively steering
Yellow = enabled, all conditions have been met to allow for
assisted/auto steering
Red = disabled, all conditions have not been met to allow for
assisted/auto steering
No icon = no assisted/auto steering system installed
Tilt correction status
Coloured = engaged, actively applying tilt correction
Red = disabled
No icon = no tilt gyro module installed on system, or tilt is
associated with assisted/auto steering system
BoomPilot status
Green = automatic
Yellow = all on
Red = off/manual
No icon = single section (no SmartCable or SDM installed on
system)
Droplet/pressure status
Coloured = engaged. The colour of the droplet is directly
associated with the current droplet size. Colour options
include: .
Crossed out = disabled
No icon = no Pressure sensor interface kit installed, no
pressure sensor monitor on the DCM
Nozzle flow status
Green = nozzle flow system calibrated with no nozzle errors
Red = nozzle flow imbalance: flow is higher or lower than the
nozzle alarm threshold
No icon = no nozzle flow monitor hardware detected
Summary of Contents for AEROS 9040
Page 1: ...Software version 4 31 U S E R M A N U A L AEROS 9040...
Page 116: ......