13
98-05304-EN R2
Aeros 9040 field computer
HOME
GUID
ANCE
FULL SCREEN
IMPLEMENT
INTR
ODUC
TION
GNSS
RA
TE C
ONTR
OL
APPENDIX
SE
TUP
Implement
Implement setup is used to establish the various settings associated
with straight mode, spreader mode, or staggered mode. Available
settings will vary depending on the specific equipment present in the
system.
This section includes setup options for these implement
configurations:
►Single section
►Section(s) with ISOBUS sprayer/spreader setup
►Multiple sections with Section driver module or Switch function
module
NOTE: For more information, see the Implement chapter of this
manual.
Implement type
Implement type selects the type of application pattern that most
closely represents your system.
● In Straight mode – the boom sections have no length and are
on a line a fixed distance from the antenna
● In Spreader mode – a virtual line is created in line with the
delivery disks from which the application section or sections can
vary in length and can be at different distances from the line
(availability depends on the specific equipment in the system)
● In Staggered mode – a virtual line is created in line with
section 1 from which the application section or sections have
no length and can be at different distances from the line
(availability depends on the specific equipment in the system)
NOTE: For more information, see "Implement type" in the Implement
chapter of this manual.
Figure 4-3: Implement type – Straight
Figure 4-4: Implement type – Spreader
Figure 4-5: Implement type – Staggered
Single section setup
Single section setup is used when a SmartCable, Section driver
module (SDM), or Switch function module (SFM) is not on the
system (that is, no section control is present). The entire boom or
delivery area is considered to be one section.
1. Press CONFIGURATION side tab
.
2. Press
Implement
.
3. Select from:
►Machine type [when available] – used to select the type of
machine that most closely represents your machine
►GNSS antenna height [when available] – used to measure the
height of the antenna from the ground
►Implement type – used to select the layout of the sections for
the applied product location
►Working width [Spreader implement type] – used to enter the
total width of the implement
►Application width [Straight implement type] – used to enter the
total width of the implement
►Droplet size monitor [when available] – used to enable droplet
size monitoring for up to five preselected sprayer tips
►Nozzle selection [when available] – used to select the type of
sprayer nozzle (series and capacity) for determining droplet
size information
Summary of Contents for AEROS 9040