3-5
(2) When function code E45 (LCD monitor item selection) is set at "1"
The LCD monitor displays the output frequency, output current, and calculated torque in a bar chart.
(The upper indicators show the unit of values displayed on the LED monitor as detailed in Section 3.3.2. The lower
ones show the running status and run command source.)
The full scale (maximum value) for each parameter is as follows:
Output frequency: Maximum frequency
Output current:
200% of inverter’s rated current
Calculated torque: 200% of rated torque generated by motor
Figure 3.4 Bar Chart
3.3.2
Monitoring the running status on the LED monitor
The items listed below can be monitored on the 7-segment LED monitor. Immediately after the power is turned ON, the
monitor item specified by function code E43 is displayed.
Pressing the key in Running mode switches between monitor items in the sequence shown in Table 3.4. The "Monitor
page #" column shows the monitor page of the items supported.
Table 3.4 Items Monitored
Monitored Items on the
LED Monitor
Example
Unit
Meaning of Displayed Value
Function
code E43
Monitor page
#
Speed Monitor
Function code E48 specifies what to be displayed.
0
0
Output frequency 1
(before slip
compensation)
Hz
Frequency actually being output (Hz)
(E48 = 0)
Output frequency 2
(after slip
compensation)
Hz
Frequency actually being output (Hz)
(E48 = 1)
Reference frequency
Hz
Frequency actually being specified (Hz)
(E48 = 2)
Motor speed
r/mi
n
Output frequency
(
Hz
)
x
120
P01
(E48 = 3)
Load shaft speed
r/mi
n
Output frequency (Hz) x E50
(E48 = 4)
Line speed
m/mi
n
Output frequency (Hz) x E50
(E48 = 5)
Display speed (%)
%
Output frequency
(
Hz
)
Maximum frequency (Hz)
x 100
(E48 = 7)
Output current
A
Current output from the inverter in RMS
3
8
Input power
kW Input power to the inverter
9
9
Calculated torque
%
Motor output torque in %
(Calculated value)
8
10
Output voltage
V
Voltage output from the inverter in RMS
4
11
Motor output
kW Motor output in kW
16
12
Load factor
%
Load factor of the motor in % as the rated
output being at 100%
15
13
Output frequency
Output current
Bar chart
Calculated torque