7-2
7.2 Run/Stop from External Switch / Contact or Pushbutton (F02 = 1)
Use an external contact or switch to Run and Stop the EQ7 drive.
Permanent Switch / Contact
G
START / STOP SWITCH (Maintained)
Connect shield to
ground terminal
Forward Command/FWD
Common/CM
Control Terminals /
User Terminals