Installing the Equipment
Page 2-14
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
ST.TM.E10033.3
2.5.4
Outputs
ASI OUT 1, 2 and 3
75
Ω
BNC connectors provide three DVB
ASI outputs from the unit.
Table 2.5: DVB ASI Connector
Pin
Signal
Centre
Signal
Screen
Ground
2.5.5
Control Interfaces
Ethernet 1 and 2
8-way, RJ45 connectors provide a
10BaseT Ethernet interface for
communications with external equipment
for control, monitoring and SI/PSI
information.
Table 2.6: Ethernet Connectors
Pin
Signal
Pin
Signal
1
Tx Out (+)
4-5
Not connected
2
Tx Out (-)
6
Rx In (-)
3
Rx In (+)
7-8
Not connected
Alarm
A 9-way, D-type, male connector
provides an alarm relay interface, which
can be used to send a signal to remote
monitoring equipment. The connector
also provides a remote reset connection.
Two relays are provided – Alarm and Fail:
•
The Alarm relay is triggered in response to an alarm condition – a
condition which is unusual but which may occur during normal
operation (such as loss of video input).
•
The Fail relay is triggered during a hardware or software failure
condition – a condition that should never occur during the normal
operating life of the equipment. The Alarm relay is also triggered
during a fail condition.