Operating the Equipment Locally
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
Page 3-97
ST.TM.E10033.3
If the specified ‘low’ preset power level entered using the keypad is
outside the valid input range, or is greater than the ‘normal’ preset power
level, a confirmation screen similar to the following is displayed which
shows the maximum/minimum value allowed. Press the Enter softkey to
accept the new value shown, or press the Quit softkey to leave the
original preset power level unchanged.
Confirmation Screen
IF Preset Power – Low
Specified Value Too Low
Select <Enter> to Set to
Enter
Minimum : -20.0 dBm
Quit
Preset Pwr Norm Option
To access the Preset Pwr Norm option, press the Preset Pwr Norm
softkey in the
Modulator
Menu
.
This enables the ‘normal’ IF output preset power level (one of settings for
the
Setup/Operations Menu
IF Power option) to be set. Use the + and –
softkeys to increment or decrement the preset power level, or enter a new
value using the keypad. Press the Enter softkey to accept the new value.
Table 3.78: Preset Pwr Norm Options
Valid Input Range
Description
Min:
–20.0 dBm
Max:
5.0 dBm
Step Size: 0.1 dBm
(Must also be greater than
the ‘low’ preset power level)
‘Normal’ IF output preset power level.
Setup/Modulator Edit
I F Pr e se t P o we r – No r ma l
+
0 . 0 d B m
—
Enter
Update using k ey p ad or softkeys
Quit
If the specified ‘normal’ preset power level entered using the keypad is
outside the valid input range, or is less than the ‘low’ preset power level, a
confirmation screen similar to the following is displayed which shows the
maximum/minimum value allowed. Press the Enter softkey to accept the
new value shown, or press the Quit softkey to leave the original preset
power level unchanged.
Confirmation Screen
IF Preset Power – Normal
Specified Value Too High
Select <Enter> to Set to
Enter
Maximum : 5.0 dBm
Quit