Operating the Equipment Locally
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
Page 3-85
ST.TM.E10033.3
Encoding Option
To access the Encoding option, press the Encoding softkey in the
RS232
(Async)
Menu
. This enables the RS-232 asynchronous data channel to be
switched on or off. Use the + and – softkeys to scroll through the choices
and then press the Enter softkey after selecting one of them.
Setup/Data/RS232 Edit
RS232 Data Encoding
+
On
—
Enter
Update using softkeys
Quit
Table 3.64: Encoding Options
Selected Option
Description
On
The RS-232 asynchronous data channel is switched on.
Off
The RS-232 asynchronous data channel is switched off.
Baud Rate Option
To access the Baud Rate option, press the Baud Rate softkey in the
RS232
(Async)
Menu
. This enables the Baud rate of the RS-232 asynchronous
data channel to be set. Use the + and – softkeys to scroll through the
choices and then press the Enter softkey after selecting one of them.
Setup/Data/RS232 Edit
RS232 Data Baud Rate
+
38400
—
Enter
Update using softkeys
Quit
Table 3.65: Baud Rate Options
Selected Option
Description
1200
1200 Baud rate.
2400
2400 Baud rate.
4800
4800 Baud rate.
9600
9600 Baud rate.
19200
19200 Baud rate.
38400
38400 Baud rate.
Data PID Option (V3.3 on)
The Data PID option is selected from the
Channel 1A Menu
by pressing the
Data PID softkey. The option is used for entering or updating data PIDs,
as required. Enter a two digit code using the keypad, then press the Enter
softkey to enter the PID.