Operating the Equipment Locally
Page 3-46
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
ST.TM.E10033.3
Setup/Serial Remote Ctrl Menu
Control
Local
*
SAbus Address
102
*
Baud Rate
4800
*
Port/Protocol
SCC3/RS232
Quit
Control Option
To access the Control option, press the Control softkey in the
Remote
Ctrl
Menu
. Use the + and – softkeys to scroll through the various options
and then press the Enter softkey after selecting one of them.
Setup/Serial Remote Ctrl Edit
Control
+
Local
—
Enter
Update using keypad or softkeys
Quit
Table 3.20: Control Options
Selected Option
Description
Local
The MCE is controlled locally.
Remote
The MCE is controlled by the RS-232/485 protocol via
the Control Remote port.
SAbus Address Option
The SAbus protocol is multi-drop, and has an address byte for
differentiating between the devices on the SAbus - the address option.
To access the SAbus Address option, press the SAbus Address softkey in
the
Remote Ctrl
Menu
. This is used for remote control of the MCE.
Use the keypad or the + and – softkeys to increment or decrement the
SAbus address, and then press the Enter softkey to accept the new value.
Setup/Serial Remote Ctrl Edit
SAbus Address
+
102
—
Enter
Update using keypad or softkeys
Quit
Table 3.21: SAbus Address Options
Selected Option
Description
Min:
49
Max:
127
Step Size:
1
SAbus address.
This option is only shown if the
MCE is already in Remote
control, to allow it to be set to
Local control. It cannot be set to
change from Local to Remote
control via the front panel
menus.