![TANDBERG E5500 Instruction Manual Download Page 45](http://html1.mh-extra.com/html/tandberg/e5500/e5500_instruction-manual_3482922045.webp)
Installing the Equipment
Page 2-16
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
ST.TM.E10033.3
Remote Control Out
A 9-way, D-type male connector provides
an RS-232/RS-422 port for remote
control of an external IRD or Modulator.
The Modulator control port may be either
RS-232 or RS-422. To select RS-232,
connect pin 4 to pin 5. This connector is
not normally used in this configuration.
Table 2.10: REMOTE CONTROL OUT Connector
Pin
Signal
Pin
Signal
1
Ground
6
MOD_RxDB
2
IRD_RxD (RS-232)
7
MOD_TxDA (RS-422)/MOD_TxD
(RS-232)
3
IRD_TxD (RS-232)
8
MOD_TxDB (RS-422)/MOD_RxD
(RS-232)
4
_SELECT_RS-232
9
MOD_RxDA (RS-422)
5
Ground
2.5.6
Option Module Connections
Analogue Video Input Option (M2/EOM1/VID)
Y/COMP, C
B
and C
R
Composite Analogue
This connector provides a differential
analogue video input for either a 625 line
composite PAL-B/D/G/H/I or 525 line
composite NTSC-M (with or without
pedestal) signal. The composite analogue
video connector doubles as the Y
component connector.
Table 2.11: Composite Analogue Video Input Connector
Item
Specification
Connector type:
BNC, female 75
Ω
Connector designation:
Y/COMP
Pin:
Centre
Signal
Shield
Ground/Chassis