Operating the Equipment Locally
Page 3-102
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
ST.TM.E10033.3
Bit-Rate Option
This option is only displayed if Output Format is set to Baseband (188),
therefore this option is not used on this equipment.
Set the required symbol rate using the Symbol Rate option on the
Setup/Operations Menu
(see page 3-23) or the
Setup/Modulator Menu
(see page 3-87), and allow the MCE to calculate the required bit-rate
automatically (see Page 3-21, Getting Started).
Scramble Option (RAS Option Module Fitted)
To access the scramble option
13
, press the Scramble softkey in the
Mux
Menu
. This enables security scrambling of the MCE transmission to be
switched on or off.
Use the + and – softkeys to scroll through the choices and then press the
Enter softkey after selecting one of them.
NOTE…
See Chapter 4, Equipment Description for details of the RAS Scrambling Module and scrambling
modes, including a list of the PIDs that are scrambled when scrambling is enabled.
Setup/Mux Edit
Scrambling
+
Off
—
Enter
Update using softkeys
Quit
Table 3.85: Scramble Options
Selected Option
Description
On (SNG Key)
MCE output is scrambled. Scrambling key used is entered using the SNG
Key Code option.
On (Fixed Key)
MCE output is scrambled. Scrambling key used in assigned by TANDBERG
Television and pre-programmed into the MCE.
Off
MCE output is not scrambled.
SNG Key Code Option (RAS Option Module Fitted)
To access the SNG Key Code option
13
, press the SNG Key Code softkey in
the
Mux Menu
. This enables the scrambling key used in SNG Key
scrambling mode to be set (see the Scramble option). The same
scrambling code must be used at the receive end to unscramble the
transmission.
Enter up to seven digits using the keypad, then press the Enter softkey to
enter the scrambling code. Note that if less then seven digits are entered,
they are prefixed with 0’s (zero) to give a seven digit code.
13
Only shown if the RAS CA module is fitted.