Operating the Equipment Locally
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
Page 3-95
ST.TM.E10033.3
Setup/Modulator Edit
F E C R a te
+
3 / 4
—
Enter
Update using softkeys
Quit
The following screen is displayed. Press the Yes softkey to switch
modulation back on and return to the menu, or press the No softkey to
return to the menu and leave modulation switched off.
Setup/Modulator Edit
F E C R a te
Y e s
3 / 4
N o
*
S w i tc h M o du l at i on Ba c k O N?
Quit
Modulation Switched Off
If modulation is switched off, the option is used in the same way as
described for modulation switched on, except that the screens to switch
modulation off and then back on are not displayed.
Spectrum Inv Option
To access the Spectrum Inv option, press the Spectrum Inv softkey in
the
Modulator
Menu
.
Pressing the Spectrum Inv softkey displays one of two screens,
depending on whether modulation is switched on or off when the softkey is
pressed.
Modulation Switched On
The following screen is displayed. In order to change the spectrum
inversion, modulation must first be switched off. Press the Yes softkey to
do this automatically (and proceed to the next screen), or press the No (or
Quit) softkey to return to the menu.
Setup/Modulator Edit
S p e ct r um In v er s io n
Yes
O f f
No
*
Switch Modulation OFF?
Quit
When modulation is switched off, the following screen is displayed. Use the
+ and – softkeys to cycle through the available settings, then press the
Enter softkey to accept the new value.