Operating the Equipment Locally
Page 3-108
Instruction Manual: evolution 5000 E5500 Mobile Contribution Encoder
ST.TM.E10033.3
Table 3.90: O/P Rate (188) Option
Selected Option
Description
188
Min:
0.000 Mbit/s
Max: 41.9314 Mbit/s
Step Size: 0.0001 Mbit/s
Multiplexer output bit-rate when in baseband output format.
Changing the bit-rate affects the automatic video bit-rate and video
resolution calculations.
If the specified bit-rate is outside the valid input range, a confirmation
screen is displayed which shows the maximum/minimum value allowed.
Press the Enter softkey to accept the new value shown, or press the Quit
softkey to leave the original bit-rate unchanged.
Confirmation Screen
Output Bit-rate (188)
Specified Value Too High
Select <Enter> to Set to
Enter
Maximum : 41.9314 Mbit/s
Quit
Spare Bit Rate Option
The Spare Bit Rate Option cannot be changed, but it does indicate how
much bit-rate is available for remultiplexing.
Input Bit Rate Option
The Input Bit Rate Option cannot be changed, but it does indicate how
much bit-rate is used by all input services.
Output Bit Rate Option
The Output Bit Rate Option cannot be changed, but it does indicate how
much output bit-rate is available.
Service Name (-) Option
Depending upon the number of inputs to the Remux card there will be
between one and thirteen service identifiers shown on the MCE display.
The service from the local Encoder (host) is identified as <Service Name>
(-) and the others are related to the input on the Remux card. <Service
Name> (1) indicates a service on input 1 etc. All services can be edited to
include or remove the servce from the output.
To change the Service Name (-) option, press the Service Name (-)
softkey in the
Services Menu
.
Use the + and – softkeys to alternate between On and Off and then press
the Enter softkey after selecting one of them.
Setup/Mux/Services Edit
Service Name
+
(-) On
—
Enter
Update using softkeys
Quit