A
Appendices
Specifications
A-3
cycle always completed
Burst
Upon trigger, outputs a single or multiple pre-
programmed numbers of waveform cycles. (Does
not apply to Sequence Mode). Burst is
programmable from 1 through 1 M cycles
Gated
Transition enables or disables generator output.
Last cycle always completed
Mixed
Same as triggered except first output cycle is
initiated by a software trigger. Consequent output
requires external triggers through the rear panel
TRIG IN connector
Trigger Characteristics
Trigger Sources
External
Rear panel BNC, or front panel manual trigger button
BUS
Trigger commands from a remote controller only
Mixed
Senses an external trigger first, consecutive triggers
are expected from remote commands only.
External Trigger Input
Impedance 10
k
Ω
Trigger Level Range
±5 V
Resolution 1
mV
Sensitivity 200
mV
Damage Level
±12 V
Frequency Range
DC to 5 MHz
Slope
Positive/Negative transitions, selectable
Minimum Pulse Width
≥
10 ns
System Delay
(Trigger input to waveform output)
6 sample clock 150 ns
Trigger Delay
(Trigger input to waveform output)
[(0; 200 ns to 20 s) + system delay]
Resolution
20
ns
Error
6 sample clock 150 ns+ 5% of setting
Re-trigger Delay
(Waveform end to waveform restart)
200 ns to 20 s
Resolution
20
ns
Error
3 sample clock 20 ns + 5% of setting
Trigger Jitter
±
1 sample clock period
Standard Waveforms
Frequency Range
Sine, Square
10 mHz to 80 MHz, Model 2074;
10 mHz to 40 MHz, Model 1074;
10 mHz to 20 MHz, Model 5064
All other waveforms
10 mHz to 20 MHz, some are usable above 20 MHz
Frequency Resolution
11 digits
Accuracy & Stability
Same as frequency standard
Sine
Start Phase Range
0 to 360.0
°
Start Phase Resolution
0.1
°
Triangle
Start Phase Range
0 to 360.0
°
Start Phase Resolution
0.1
°
Square
Summary of Contents for 5064
Page 26: ...1 5 Figure 1 2 ArbConnection The Control Panels Figure 1 3 ArbConnection The Wave Composer...
Page 71: ...2074 User Manual 2 18 This page intentionally left blank...
Page 145: ...2074 User Manual 3 74 Figure 3 48 Reading the 2074 Internal Temperature...
Page 220: ...4 ArbConnection Logging SCPI Commands 4 75 Figure 4 58 Log File Example...
Page 221: ...2074 User Manual 4 76 This page was intentionally left blank...
Page 333: ...2074 User Manual 7 2...
Page 359: ...2074 User Manual 7 28 This page was intentionally left blank...
Page 360: ...Appendices Appendix Title Page A Specifications A 1 1...
Page 361: ...2074 User Manual 2...