1-16
Burst
The burst mode is an extension of the triggered mode where the
Model 2074 can be programmed to output a pre-determined
number of waveforms. Note that the burst run mode cannot be
applied to sequenced waveform because the two functions share
the same circuit and therefore, whenever counted burst is selected
for sequenced waveforms, the generator will issue a setting conflict
error.
Table
1-1, Run Modes and Trigger Source Options Summary
Run Mode
Trigger Option
Status
Continuous
External
Bus
Mixed
Delayed Trigger
Re-Trigger
(*) Output signal is toggled on and off
using interface triggers
Disabled
Active(*)
Disabled
Active
Disabled
Triggered
External
Bus
Mixed
Delayed Trigger
Re-Trigger
Active
Active
Active
Active
Active
Counted Burst
External
Bus
Mixed
Delayed Trigger
Re-Trigger
(*) Not in conjunction with Re-Trigger
(**) Not in conjunction with Mixed
Active
Active
Active(*)
Active
Active(**)
Gated
External
Bus
Mixed
Delayed Trigger
Re-Trigger
Active
Active
Disabled
Active
Disabled
Gated
In gated mode, the 2074 generates output waveforms between two
gating signal. Only hardware triggers can be used to open and
close the gate. The gate opens on the first trigger transition and
closes on the second transition. Trigger level and trigger slope are
programmable. Trigger delay and re-trigger do not apply to the
gated run mode.
Summary of Contents for 5064
Page 26: ...1 5 Figure 1 2 ArbConnection The Control Panels Figure 1 3 ArbConnection The Wave Composer...
Page 71: ...2074 User Manual 2 18 This page intentionally left blank...
Page 145: ...2074 User Manual 3 74 Figure 3 48 Reading the 2074 Internal Temperature...
Page 220: ...4 ArbConnection Logging SCPI Commands 4 75 Figure 4 58 Log File Example...
Page 221: ...2074 User Manual 4 76 This page was intentionally left blank...
Page 333: ...2074 User Manual 7 2...
Page 359: ...2074 User Manual 7 28 This page was intentionally left blank...
Page 360: ...Appendices Appendix Title Page A Specifications A 1 1...
Page 361: ...2074 User Manual 2...