E09.012.246 Manual S-WG
64
10.6
Schornsteinfeger function
The purpose of this function is to have an easy interface for the
"Schornsteinfegers" in Germany, to be able to do their required
testing on the water heater. This is a simplified function similar to
the normal service function of the water heater.
When the "Schornsteinfeger" button is pressed for 3 seconds:
the heater will fire at
minimum firing rate (%)
In this state the display shows:
F l u e
s e r v i c e
m o d e
P o w e r
:
M i n i m u m
When the button is pressed (briefly) again:
the heater will fire at
50% firing rate
In this state the display shows:
F l u e
s e r v i c e
m o d e
P o w e r
:
5 0 %
When the button is pressed (briefly) again:
the heater will fire at
maximum firing rate (%)
In this state the display shows:
F l u e
s e r v i c e
m o d e
P o w e r
:
M a x i m u m
When the button is pressed briefly again:
the heater will return to the normal operation mode.
The "Schornsteinfeger" function is switched off.
NOTES:
When the heater is burning during Schornsteinfeger function
(when top display line shows "Flue service mode") and no button
is pressed for 12 minutes, the water heater will return automati-
cally to the normal operation mode. The "Schornsteinfeger" func-
tion will be switched off.
The "Schornsteinfeger function" can be activated for the user by
programming a parameter (P5 BK)
All regular temperature safety controls remain active and the wa-
ter heater pump and system pump are running.
Summary of Contents for S-WG 100
Page 13: ...E09 012 246 Manual S WG 14 3 3 S WG tanks 300 Ltr 450 Ltr ...
Page 14: ...E09 012 246 Manual S WG 15 750 Ltr ...
Page 33: ...E09 012 246 Manual S WG 34 7 4 Electrical schematics ...
Page 34: ...E09 012 246 Manual S WG 35 ...
Page 122: ...E09 012 246 Manual S WG 123 notes ...
Page 123: ...E09 012 246 Manual S WG 124 notes ...
Page 124: ......