E09.012.246 Manual S-WG
42
9.2
Water heater and tank: connections and connection sizes
9.2.1
C
ONNECTING THE TANK TO THE WATER HEATER
Connect the
pump
by means of couplings and a piece of copper pipe to connection A of the water heater
(note the flow direction of the pump).
Connect the inlet of the pump to the
upper
of the two close above each other located connections of the
tank, labelled
‘return to water heater’.
Connect connection B of the water heater to the
lower
of the two close above each other located connec-
tions of the tank, labelled
‘flow from water heater’. Also make a tap point in this line at the lowest point.
WATER HEATER CONNECTIONS
A = inlet cold water
B = outlet hot water
C = overpressure safety valve
D =
gas