E09.012.246 Manual S-WG
27
B: Twin pipe system with separate pipes and concentric roof terminal.
Example B
The total resistance is less than 200 Pa. This flue gas/air supply system is functional.
120
2
m
2
m
2m
2
m
2
m
2m
Water heater type:
S-WG 120
Flue gas
Diameter: 100 mm.
Number
Pa
Pa total
Straight tube m¹
total
6
6.5
39
Bend
90°
2
6.5
13
Roof terminal
concentric
150/100
1
45
45
Adaptor conc./par.
150/100
1
22
22
Total resistance flue gas outlet:
119
A
ir
su
p-
ply
Diameter: 100 mm.
Number
Pa
Pa total
Straight tube m¹
total
6
4
24
Bend
90°
2
4
8
Total resistance air supply:
32
Total resistance flue gas outlet and air supply:
151 Pa