E09.012.246 Manual S-WG
54
9.6
Elaborated examples
To work out the examples in this section, the rules of page 46 are given again:
9.6.1
O
NE
S-WG120
WATER HEATER WITH ONE
450-
LITRES TANK
Water heater and tank connections:
For this system rule 1 must be applied, so only one pipe size is needed.
No numbering of water heaters, tanks and connections is required.
From table
WH-120
: for 1 water heater is FF = RR = 54
1.5 [mm
mm]
From table
T-120
: for 1 tank is A1 = B1 = 54
1.5 [mm
mm]
For this system pipes sized at least 54
1.5 [mm
mm] are required for all connections.
Equivalent length:
From table
EL
:
The maximum total length of flow and return pipes 54
1.5 [mm
mm] is 24.2 m.
So when 54
1.5 [mm
mm] is applied, the physical distance between water heaters and tanks may be half of
this,
so ~ 12 m, at max. In case bends and/or valves are used, this distance becomes less than 12 m. Use the table.
tank 450 L
boiler S-
WG120
FF
FF
RR
RR
1
RR
FF
KOUD IN
1
B1 A1
1. Assigning codes to a one water heater installation:
There’s only one flow pipe, encoded FF, and one return pipe, encoded RR. For the right diameters
see § 9.4.1, pick the table of the corresponding water heater type.
2. Assigning codes to cascades: two or more water heaters to connect:
First number the water heaters: water heater-
1 is the one that‘s situated the furthest away from the
tank(s).
Connections directly to the water heaters: F1 = R1 = 54
1.5 (mm
mm)
Number the horizontal flow pipes between water heaters: from F1 at water heater-1 to FF at water
heater-number-last.
Number the horizontal return pipes between water heater
s ‘reversely’: from R1 at water heater-
number-last to RR at water heater-1.
3. Assigning codes to tank connections:
-
Tank connections: A1 and B1 (entrance and exit). The values are found in the tank tables (§ 9.4.2)
-
Pipes between these connections: FF and RR, values from the water heater tables (§ 9.4.1).
-
For a given cascade, A1 equals B1.
Example 1
COLD IN
Summary of Contents for S-WG 100
Page 13: ...E09 012 246 Manual S WG 14 3 3 S WG tanks 300 Ltr 450 Ltr ...
Page 14: ...E09 012 246 Manual S WG 15 750 Ltr ...
Page 33: ...E09 012 246 Manual S WG 34 7 4 Electrical schematics ...
Page 34: ...E09 012 246 Manual S WG 35 ...
Page 122: ...E09 012 246 Manual S WG 123 notes ...
Page 123: ...E09 012 246 Manual S WG 124 notes ...
Page 124: ......