REFLECTOMETER
49
Fig.51
In Fig.51:
1 - REF is on
2 - the connected pair of wires
3 - "hot" buttons
4 - value of the Shortening Factor
5 - indicator showing continuation of the table if all wires and cable screen are tested
6 - numbers of pairs of wires
7 - results of measurements (distances and levels of a response)
8 - two wires from the different twisted pairs ("non-linked pairs"), marked by white color
9 - two wires from the same twisted pair ("linked pairs"), marked by blue color
10 - the measured distance to heterogeneity with the maximum level of a response
11 - response level from heterogeneity
Available actions:
Shortening Factor setting;
cable type setting;
test of the connected pair of wires in the manual mode;
test of all combinations of pairs of cable in the AUTOMATED mode.
Controls:
Button
Action
Tabular cursor move
F1, ENTER
Turning on the MANUAL mode of test of single pair of wires
F2
Turning on/off Shortening Factor
F3
Turning on the single test on the connected pair of wires
F4
Turning on AUTOMATED mode
ESC, MODE
Exit to the Analyzer main menu
FUNC
Turning on SWITCH SETTING mode