SOFTWARE
110
2.
Click on an inactive table (to activate it).
3.
Set the cursor in the Switch table to another pair of wires. The activated measurement
table displays the parameters of the detected responses on the second pair. Two
reflectograms corresponding to the results of measurements on one and on the other pairs
will be displayed on the screen.
4.
To analyze the results (two tables of measurements and the reflectograms).
5. Comparison of the results of two measurements taken from different ends of the cable.
1.
Activate the table "Set 1".
2.
Test cable in AUTOMATED mode.
3.
Save the test results
(item 8.5.6.).
4.
Go to the other end of the cable.
5.
Connect the cable to the main unit.
6.
Turn on the Analyzer and the PC.
7.
Run the program (REF).
8.
Perform testing in AUTOMATED mode.
9.
Download the file with the test results of this cable from the opposite end
10.
Turn on the
COMPARISON MODE
(item 8.5.7).
11.
Analyze the result.
If the cable does not have heterogeneities, the results in both tables should be the same or
very close (in the Switch table, no pair should be highlighted in red). Reflectograms
must also be
the same.