SOFTWARE
106
Fig.85
Fig. 85 (as an example) compares the test results of a telephone cable. The tabular cursor
(Fig.85, item 2) is set to the pair "3-6" (the pair number is highlighted in red), where the changes
were detected.
Analyzing the tables and reflectogram, it can be concluded that a new heterogeneity appears
at a distance of 40 meters (about 3 meters from the end of the cable).
This heterogeneity is visible on the reflectogram (Fig.85, item 6).
Messages in the information line when comparing test results
Message
Explanations
No data in the file for this pair!
There are no saved measurement results on this pair. The
results of current measurements have nothing to compare.
No new measurements for this
pair!
The saved file contains the measurement results. There were no
measurements in the current measurement cycle.
In the file - the noise. In the
current data - no.
In the saved file, an unacceptable level of “noise” was recorded
on this pair. This level was not detected in the current
measurement cycle.
In the file - more than 3v. In
the current data - no.
In the saved file, a voltage of more than 3V was recorded in this
pair. There are no measurements in the current cycle
In the current data - the noise.
In the file - no.
In the current measurement cycle, an unacceptable level of
"noise" was detected in this pair. There was no "noise" in the
saved file in this pair.
In the current data - more
than 3v. In the file - no.
In the current measurement cycle, a voltage of more than 3V is
detected. In the saved file, this pair was de-energized.
In the file - the noise. In the
current data - more than 3v.
In the saved file, an unacceptable level of "noise" was detected
on this pair. In the current measurement cycle on this pair, the
voltage is more than 3V.