Removing Power From the Server
The following table identifies the components in each category.
Component service
Category
Component
Service information
Notes
Hot-service, replaceable by
customer
Drive
Drive must be offline.
Drive filler
Needed to preserve proper
interior air flow.
Power supply
“Servicing Power Supplies” on page 87
Hot-service if two power
supplies are in use. Otherwise,
cold-service.
Fan
“Servicing Fan Modules” on page 77
Removal of a fan requires
replacement within 5 minutes
to avoid overheating.
Cold-service, replaceable
by customer
DIMMs
PCIe cards
“Servicing PCIe Cards” on page 103
Battery
“Servicing the Battery” on page 113
SC PROM
“Servicing the Motherboard” on page 117
eUSB Drive
Cold-service, replaceable
by authorized service
personnel
Motherboard
“Servicing the Motherboard” on page 117
Transfer system configuration
PROM to new motherboard.
Drive backplane
LED indicator modules
(front left and front right)
Related Information
■
“Internal Component Locations” on page 20
Removing Power From the Server
These topics describe how to power off the server.
Step
Description
Links
1.
Prepare the server for powering off.
“Prepare to Power Off the Server” on page 51
2.
Power off the server by one of three methods.
“Power Off the Server (Oracle ILOM)” on page 52
50
SPARC S7-2L Server Service Manual • March 2017
Summary of Contents for S7-2L
Page 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Page 2: ......
Page 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Page 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Page 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Page 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Page 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Page 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Page 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Page 156: ...156 SPARC S7 2L Server Service Manual March 2017...